High-sensitivity troponin assays for early rule-out of acute myocardial infarction in people with acute chest pain: a systematic review and economic evaluation

Author:

Westwood Marie1ORCID,Ramaekers Bram2ORCID,Grimm Sabine2ORCID,Worthy Gill1ORCID,Fayter Debra1ORCID,Armstrong Nigel1ORCID,Buksnys Titas1ORCID,Ross Janine1ORCID,Joore Manuela2ORCID,Kleijnen Jos13ORCID

Affiliation:

1. Kleijnen Systematic Reviews Ltd, York, UK

2. Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University, Maastricht, the Netherlands

3. School for Public Health and Primary Care, Care and Public Health Research Institute, Maastricht University, Maastricht, the Netherlands

Abstract

Background Early diagnosis of acute myocardial infarction is important, but only 20% of emergency admissions for chest pain will actually have an acute myocardial infarction. High-sensitivity cardiac troponin assays may allow rapid rule out of myocardial infarction and avoid unnecessary hospital admissions. Objectives To assess the clinical effectiveness and cost-effectiveness of high-sensitivity cardiac troponin assays for the management of adults presenting with acute chest pain, in particular for the early rule-out of acute myocardial infarction. Methods Sixteen databases were searched up to September 2019. Review methods followed published guidelines. Studies were assessed for quality using appropriate risk-of-bias tools. The bivariate model was used to estimate summary sensitivity and specificity for meta-analyses involving four or more studies; otherwise, random-effects logistic regression was used. The health economic analysis considered the long-term costs and quality-adjusted life-years associated with different troponin testing methods. The de novo model consisted of a decision tree and a state–transition cohort model. A lifetime time horizon (of 60 years) was used. Results Thirty-seven studies (123 publications) were included in the review. The high-sensitivity cardiac troponin test strategies evaluated are defined by the combination of four factors (i.e. assay, number and timing of tests, and threshold concentration), resulting in a large number of possible combinations. Clinical opinion indicated a minimum clinically acceptable sensitivity of 97%. When considering single test strategies, only those using a threshold at or near to the limit of detection for the assay, in a sample taken at presentation, met the minimum clinically acceptable sensitivity criterion. The majority of the multiple test strategies that met this criterion comprised an initial rule-out step, based on high-sensitivity cardiac troponin levels in a sample taken on presentation and a minimum symptom duration, and a second stage for patients not meeting the initial rule-out criteria, based on presentation levels of high-sensitivity cardiac troponin and absolute change after 1, 2 or 3 hours. Two large cluster randomised controlled trials found that implementation of an early rule-out pathway for myocardial infarction reduced length of stay and rate of hospital admission without increasing cardiac events. In the base-case analysis, standard troponin testing was both the most effective and the most costly. Other testing strategies with a sensitivity of 100% (subject to uncertainty) were almost equally effective, resulting in the same life-year and quality-adjusted life-year gain at up to four decimal places. Comparisons based on the next best alternative showed that for willingness-to-pay values below £8455 per quality-adjusted life-year, the Access High Sensitivity Troponin I (Beckman Coulter, Brea, CA, USA) [(symptoms > 3 hours AND < 4 ng/l at 0 hours) OR (< 5 ng/l AND Δ < 5 ng/l at 0 to 2 hours)] would be cost-effective. For thresholds between £8455 and £20,190 per quality-adjusted life-year, the Elecsys® Troponin-T high sensitive (Roche, Basel, Switzerland) (< 12 ng/l at 0 hours AND Δ < 3 ng/l at 0 to 1 hours) would be cost-effective. For a threshold > £20,190 per quality-adjusted life-year, the Dimension Vista® High-Sensitivity Troponin I (Siemens Healthcare, Erlangen, Germany) (< 5 ng/l at 0 hours AND Δ < 2 ng/l at 0 to 1 hours) would be cost-effective. Conclusions High-sensitivity cardiac troponin testing may be cost-effective compared with standard troponin testing. Study registration This study is registered as PROSPERO CRD42019154716. Funding This project was funded by the National Institute for Health Research (NIHR) Evidence Synthesis programme and will be published in full in Health Technology Assessment; Vol. 25, No. 33. See the NIHR Journals Library website for further project information.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Reference318 articles.

1. Chalkidou A, Erskine J, Radhakrishnan Kartha M, Langford T, Macmillan T, Keevil S. Review Report of DG15: Myocardial Infarction (Acute): Early Rule Out Using High-Sensitivity Troponin Tests (Elecsys Troponin T high-sensitive, ARCHITECT STAT High Sensitive Troponin-I and AccuTnI+3 Assays). London: King’s Technology Evaluation Centre, King’s College London; 2017.

2. High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: a systematic review and cost-effectiveness analysis;Westwood;Health Technol Assess,2015

3. The health care burden of acute chest pain;Goodacre;Heart,2005