High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: a systematic review and cost-effectiveness analysis

Author:

Westwood Marie1,van Asselt Thea2,Ramaekers Bram2,Whiting Penny1,Thokala Praveen3,Joore Manuela2,Armstrong Nigel1,Ross Janine1,Severens Johan4,Kleijnen Jos5

Affiliation:

1. Kleijnen Systematic Reviews Ltd, York, UK

2. Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Centre, Maastricht, The Netherlands

3. Health Economics and Decision Science Group, School of Health and Related Research (ScHARR), University of Sheffield, Sheffield, UK

4. Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, The Netherlands

5. School for Public Health and Primary Care (CAPHRI), Maastricht University, Maastricht, The Netherlands

Abstract

BackgroundEarly diagnosis of acute myocardial infarction (AMI) can ensure quick and effective treatment but only 20% of adults with emergency admissions for chest pain have an AMI. High-sensitivity cardiac troponin (hs-cTn) assays may allow rapid rule-out of AMI and avoidance of unnecessary hospital admissions and anxiety.ObjectiveTo assess the clinical effectiveness and cost-effectiveness of hs-cTn assays for the early (within 4 hours of presentation) rule-out of AMI in adults with acute chest pain.MethodsSixteen databases, including MEDLINE and EMBASE, research registers and conference proceedings, were searched to October 2013. Study quality was assessed using QUADAS-2. The bivariate model was used to estimate summary sensitivity and specificity for meta-analyses involving four or more studies, otherwise random-effects logistic regression was used. The health-economic analysis considered the long-term costs and quality-adjusted life-years (QALYs) associated with different troponin (Tn) testing methods. The de novo model consisted of a decision tree and Markov model. A lifetime time horizon (60 years) was used.ResultsEighteen studies were included in the clinical effectiveness review. The optimum strategy, based on the Roche assay, used a limit of blank (LoB) threshold in a presentation sample to rule out AMI [negative likelihood ratio (LR–) 0.10, 95% confidence interval (CI) 0.05 to 0.18]. Patients testing positive could then have a further test at 2 hours; a result above the 99th centile on either sample and a delta (Δ) of ≥ 20% has some potential for ruling in an AMI [positive likelihood ratio (LR+) 8.42, 95% CI 6.11 to 11.60], whereas a result below the 99th centile on both samples and a Δ of < 20% can be used to rule out an AMI (LR– 0.04, 95% CI 0.02 to 0.10). The optimum strategy, based on the Abbott assay, used a limit of detection (LoD) threshold in a presentation sample to rule out AMI (LR– 0.01, 95% CI 0.00 to 0.08). Patients testing positive could then have a further test at 3 hours; a result above the 99th centile on this sample has some potential for ruling in an AMI (LR+ 10.16, 95% CI 8.38 to 12.31), whereas a result below the 99th centile can be used to rule out an AMI (LR– 0.02, 95% CI 0.01 to 0.05). In the base-case analysis, standard Tn testing was both most effective and most costly. Strategies considered cost-effective depending upon incremental cost-effectiveness ratio thresholds were Abbott 99th centile (thresholds of < £6597), Beckman 99th centile (thresholds between £6597 and £30,042), Abbott optimal strategy (LoD threshold at presentation, followed by 99th centile threshold at 3 hours) (thresholds between £30,042 and £103,194) and the standard Tn test (thresholds over £103,194). The Roche 99th centile and the Roche optimal strategy [LoB threshold at presentation followed by 99th centile threshold and/or Δ20% (compared with presentation test) at 1–3 hours] were extendedly dominated in this analysis.ConclusionsThere is some evidence to suggest that hs-CTn testing may provide an effective and cost-effective approach to early rule-out of AMI. Further research is needed to clarify optimal diagnostic thresholds and testing strategies.Study registrationThis study is registered as PROSPERO CRD42013005939.FundingThe National Institute for Health Research Health Technology Assessment programme.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Reference325 articles.

1. Office for National Statistics (ONS). Death Registration Summary Tables – England and Wales, 2011 (Final). 2012. URL: www.ons.gov.uk/ons/publications/re-reference-tables.html?edition=tcm%3A77–276695 (accessed 28 August 2013).

2. The health care burden of acute chest pain;Goodacre;Heart,2005

3. Health and Social Care Information Centre (HSCIC). Hospital Episode Statistics, Admitted Patient Care – England 2011–12: Primary Diagnosis, 4 Characters Table. Health & Social Care Information Centre (HSCIC), 2012. URL: www.hscic.gov.uk/catalogue/PUB08288 (accessed 28 August 2013).

4. Impact of European Society of Cardiology/American College of Cardiology guidelines on diagnostic classification of patients with suspected acute coronary syndromes;Collinson;Ann Clin Biochem,2003

5. Management of acute myocardial infarction in patients presenting with ST-segment elevation. The Task Force on the Management of Acute Myocardial Infarction of the European Society of Cardiology;Van de Werf;Eur Heart J,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3