Diagnostic Performance of Quantitative κ and λ Free Light Chain Assays in Clinical Practice

Author:

Katzmann Jerry A,Abraham Roshini S1,Dispenzieri Angela1,Lust John A1,Kyle Robert A1

Affiliation:

1. Division of Clinical Biochemistry and Immunology, Department of Laboratory Medicine and Pathology, and Division of Hematology, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, MN

Abstract

Abstract Background: The quantitative assay for free light chains (FLCs) is a recently introduced commercial test reported to be sensitive and specific for detecting FLC diseases such as primary systemic amyloidosis (AL), light chain deposition disease (LCDD), nonsecretory multiple myeloma (NSMM), and light chain multiple myeloma. We evaluated its diagnostic performance in clinical practice. Methods: All FLC clinical test results generated in 2003 were abstracted from the Laboratory Information System. Diagnoses were obtained from the Dysproteinemia database and the patient medical history. Results: In 2003, we received samples for FLC assays from 1020 Mayo Clinic patients. The majority of these patients (88%) had bone marrow-derived monoclonal plasma cell disorders (PCDs). The 121 patients who did not have monoclonal gammopathy all had FLC κ/λ ratios within the range of values obtained for a reference population in our laboratory. Among the patients with monoclonal gammopathies were patients with multiple myeloma (330), AL (269), monoclonal gammopathy of undetermined significance (114), smoldering multiple myeloma (72), plasmacytoma (22), NSMM (20), macroglobulinemia (9), LCDD (7), and a variety of other PCDs. Among the 110 AL patients who had not been previously treated and who had a FLC assay performed within 120 days of diagnosis, the FLC κ/λ ratio was positive in 91% compared with 69% for serum immunofixation electrophoresis (IFE) and 83% for urine IFE. The combination of serum IFE and serum FLC assay detected an abnormal result in 99% (109 of 110) of patients with AL. Conclusion: The performance of the FLC assay in this analysis of clinical laboratory data is consistent with results from published retrospective validation studies.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 218 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3