Detecting Long-term Drift in Reagent Lots

Author:

Liu Jiakai1,Tan Chin Hon1,Loh Tze Ping2,Badrick Tony3

Affiliation:

1. Department of Industrial and Systems Engineering, National University of Singapore, Singapore

2. Department of Laboratory Medicine, National University Hospital, Singapore

3. Faculty of Health Sciences and Medicine, Bond University, Queensland, Australia

Abstract

Abstract BACKGROUND Between-reagent lot verification is a routine laboratory exercise in which a set of samples is tested in parallel with an existing reagent lot and a candidate reagent lot (before the candidate lot is committed to test patient samples). The exercise aims to verify and maintain consistency in the analytical performance of a test. We examined the limitations of a routine between-reagent lot verification procedure in detecting long-term analytical drift and looked for a more sensitive alternative. METHOD Via numerical simulations, we examined the statistical power of the current regression-based (weighted Deming regression) procedure for between-reagent lot verification in detecting proportional bias and constant bias. An alternative procedure applying the Student t-test to separately examine cumulative regression slopes and intercepts across multiple reagent lots was proposed and evaluated by numerical simulations. RESULTS The regression-based procedure had poor statistical power in detecting proportional bias and constant bias when small numbers of samples were used in each between-reagent lot verification exercise. Furthermore, the method failed to detect long-term drifts in analytical performance. The proposed approach based on the Student t-test can detect long-term (cumulative) drifts in regression slopes and intercepts. This method detected a mild downward drift in the serum sodium assay in our hospital that was missed by routine between-reagent lot verification. CONCLUSIONS The proposed method objectively and systematically detects long-term proportional and constant bias separately. However, the statistical power of this procedure remains unsatisfactory when used with small sample sizes. Sharing of information between laboratories may provide sufficient statistical power to detect clinically important analytical shifts.

Funder

Ministry of Education - Singapore

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3