Immunoassay for Sex Hormone-Binding Globulin in Undiluted Serum Is Influenced by High-Molecular-Mass Aggregates

Author:

Thaler Markus1,Metzger Jochen1,Schreiegg Anita1,Denk Barbara2,Gleixner Andreas2,Hauptmann Hagen3,Luppa Peter B1

Affiliation:

1. Institute for Clinical Chemistry and Pathobiochemistry, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany

2. Roche Diagnostics GmbH, Werk Penzberg, Penzberg, Germany

3. Institute of Organic Chemistry, Universität Regensburg, Regensburg, Germany

Abstract

AbstractBackground: The new Elecsys® chemiluminescence assay for measurement of homodimeric sex hormone-binding globulin (SHBG) was designed for use with undiluted serum, in contrast to other methods that require predilution. During assay development, unexpected calibration difficulties were observed that were attributable to particular biochemical properties of the highly concentrated SHBG in solution.Methods: We used a surface plasmon resonance (SPR) biosensor, which enables biomolecular interaction analysis of SHBG, and size-exclusion chromatography for this investigation. The immunoassay was evaluated for imprecision, linearity, and suitability of the dilution medium, and the method was compared with an IRMA for SHBG.Results: The SPR biosensor characterized the special protein properties of SHBG in various concentrations. Above 200 nmol/L there was a strong tendency toward formation of high-molecular-mass aggregates. This was also detectable by size-exclusion chromatography and could be reversed by simple dilution of the sample. On the basis of these results, the dynamic measuring range of the SHBG assay is restricted to 0.350–200 nmol/L. Assay evaluation on a 2010 analyzer revealed excellent precision (CV ≤2.5%). Mean recoveries were 84.2–98.8%. Intermethod comparison with an IRMA yielded a satisfactory concordance of the two assays with a Spearman correlation coefficient of 0.8807.Conclusions: Aggregates of human SHBG may have a detrimental impact on the accurate measurement of the protein if measurements are performed with undiluted serum samples. Further work is needed to clarify whether these high-molecular-mass aggregates influence the free fraction of steroid hormones in vivo.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3