Simulation Models of Misclassification Error for Single Thresholds of High-Sensitivity Cardiac Troponin I Due to Assay Bias and Imprecision

Author:

Lyon Andrew W1,Kavsak Peter A2,Lyon Oliver A S1,Worster Andrew3,Lyon Martha E1

Affiliation:

1. Department of Pathology and Laboratory Medicine, Saskatoon Health Region, Saskatoon, SK, Canada

2. Department of Pathology and Molecular Medicine and

3. Division of Emergency Medicine, McMaster University, Hamilton, ON, Canada

Abstract

Abstract BACKGROUND Clinical outcome studies for cardiac troponins (cTn) are expensive and difficult to design owing to variation in patients, in the assays, and in the incidence of different types of myocardial infarction (MI). To overcome these difficulties, simulation models were used to estimate the rate of misclassification error for MI and risk prediction resulting from assay bias and imprecision. METHODS Finite mixture analysis of Abbott high-sensitivity cTnI (hs-cTnI) results at time 0 h in patients presenting early with acute coronary syndrome (ACS) symptoms to the emergency department (ED) [n = 145, Reducing the Time Interval for Identifying New Guideline (RING) study] allowed derivation of a simulation data set (n = 10000). hs-cTnI concentrations were modified by addition of bias or imprecision error. The percentage of all 10000 modified hs-cTnI results that were misclassified for MI at thresholds of 2, 5, 26.2, and 52 ng/L was determined by Monte Carlo simulation. Analyses were replicated with an all-comer emergency department (ED) population (n = 1137) ROMI (Optimum Troponin Cutoffs for ACS in the ED) study. RESULTS In the RING study, simulation at 26.2-ng/L (99th percentile) and 52-ng/L thresholds were affected by both bias ±2 ng/L and imprecision (10%–20%) and had misclassification rates of 0.4% to 0.6%. Simulations at the 2-ng/L and 5-ng/L thresholds were only affected by bias. Misclassification rates at bias of ±1 ng/L were 10% for the 2-ng/L threshold, and 5% for the 5-ng/L threshold. CONCLUSIONS Simulation models predicted that hs-cTnI results are seldom misclassified (<1% of patients) when interpretative thresholds are near or exceed the overall 99th percentile. However, simulation models also predicted that low hs-cTnI results, as recommended in guidelines, are prone to misclassification of 5%–10% of patients.

Funder

Abbott Laboratories

Canadian Institutes of Health Research for the RING

Abbott Point of Care

Beckman Coulter

Ortho Clinical Diagnostics

Roche Diagnostics

Siemens Healthcare Diagnostics

Canadian Institutes of Health Research

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 61 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3