Differences in Recognition of the 1st WHO International Reference Reagents for hCG-Related Isoforms by Diagnostic Immunoassays for Human Chorionic Gonadotropin

Author:

Sturgeon Catharine M1,Berger Peter2,Bidart Jean-Michel3,Birken Steven4,Burns Chris5,Norman Robert J6,Stenman Ulf-Håkan7,

Affiliation:

1. Department of Clinical Biochemistry, Royal Infirmary, Edinburgh, UK

2. Institute for Biomedical Aging Research, Austrian Academy of Sciences, Innsbruck, Austria

3. Department of Clinical Biology, Institut Gustave-Roussy, Villejuif, France

4. Department of Obstetrics and Gynecology, College of Physicians and Surgeons of Columbia University, NY, NY

5. National Institute of Biological Standards and Control, Potters Bar, UK

6. Research Centre for Reproductive Health, Department of Obstetrics and Gynaecology, University of Adelaide, The Queen Elizabeth Hospital, Woodville, Australia

7. Department of Clinical Chemistry, Helsinki University Central Hospital, Finland

Abstract

Abstract Background: The 1st WHO International Reference Reagents (IRRs) for 6 human chorionic gonadotropin (hCG)-related molecular variants, highly purified and calibrated in substance concentrations by the IFCC Working Group for hCG, permit experimental elucidation of what commercially available hCG methods measure in molar terms and enable assessment of their fitness for clinical purposes. Methods: Pools containing known amounts of the IRRs spiked into normal human serum were issued to participants through the UK National External Quality Assessment Service for hCG for a period of 7 years. Among 16 assays used, 4 recognized only hCG, whereas 6 recognized hCG and its free β-subunit (hCGβ), and 6 recognized hCG, hCGβ, and the beta core fragment. Results: Differences in calibration of current hCG assays are moderate. Mean recovery of the current International Standard (IS), hCG IS 75/589, was 107% (range 93% to 126%), whereas that of the IRR 99/688 for hCG was 139% (range 109%–164%). Between-method variation for the latter (CV 12.3%) was also greater than for IS 75/589 (CV 8.8%). Recognition of hCGβ varied markedly (CV 37%). Most assays overestimated it, but 2 RIAs produced results that were slight underestimations. Recognition of the beta core fragment was even more variable (CV 57%) and was closest to equimolarity for the RIAs. Conclusions: Assays for hCG show considerable variation in their recognition of various forms of hCG, and this variablility is the most important cause of method-related differences in hCG results in serum and an even more important cause of method-related differences in urine measurements. Equimolar recognition of the major hCG isoforms is essential if between-method comparability for hCG is to be improved.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 113 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3