Impact of Biotin Supplementation on Human Chorionic Gonadotropin Immunoassays Utilizing Biotin-Streptavidin Binding Methods in Urine

Author:

Goodrum Jenna M1ORCID,Nair Vinod S1,Moore Chad1,Crouch Andre K1,Eichner Daniel1,Miller Geoffrey D1

Affiliation:

1. Sports Medicine Research and Testing Laboratory , Salt Lake City, UT , United States

Abstract

Abstract Background Human chorionic gonadotropin (hCG) detection is indicative of pregnancy and can be indicative of some forms of cancerous tumors. The hCG drug itself, however, is a performance enhancing substance used by male athletes to increase testosterone production. Antidoping testing for hCG is conducted in urine, often on immunoanalyzer platforms, many of which utilize biotin-streptavidin dependent immunoassays in which the presence of biotin in samples is a known confounding factor. While biotin interference in serum has been well-studied, the extent of biotin interference in urine has not. Methods Ten active male individuals underwent a 2-week hCG administration protocol concurrent with supplementation with biotin (20 mg/day) or placebo. Urine and serum samples were collected throughout the study and analyzed for hCG and biotin concentrations. Results Urinary biotin levels in the hCG + biotin group increased 500-fold over baseline and 29-fold over corresponding serum biotin levels after biotin supplementation. When using a biotin-dependent immunoassay, the hCG + placebo group produced hCG-positive results (hCG ≥ 5 mIU/mL) in 71% of urine samples, while the hCG + biotin group produced positive results in only 19% of samples. Both groups had elevated hCG values in serum measurements by a biotin-dependent immunoassay and in urine when using a biotin-independent immunoassay. Urinary hCG measurements and biotin levels from the hCG + biotin group showed a negative correlation (Spearman r = −0.46, P < 0.0001) when measured using a biotin-dependent immunoassay. Conclusions Biotin supplementation can severely suppress urinary hCG values in assays utilizing biotin-streptavidin binding methods and therefore these types of assays are not recommended for use in urine samples containing high levels of biotin. Clinicaltrials.gov Registration Number: NCT05450900

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3