Quality Control and Peak Finding for Proteomics Data Collected from Nipple Aspirate Fluid by Surface-Enhanced Laser Desorption and Ionization

Author:

Coombes Kevin R1,Fritsche Herbert A2,Clarke Charlotte3,Chen Jeng-neng4,Baggerly Keith A1,Morris Jeffrey S1,Xiao Lian-chun1,Hung Mien-Chie4,Kuerer Henry M56

Affiliation:

1. Biostatistics

2. Laboratory Medicine

3. Ciphergen Biosystems, Inc., 6611 Dumbarton Circle, Fremont, CA 94555

4. Molecular and Cellular Oncology, and

5. Surgical Oncology, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Box 447, Houston TX 77030

6. Departments of

Abstract

Abstract Background: Recently, researchers have been using mass spectroscopy to study cancer. For use of proteomics spectra in a clinical setting, stringent quality-control procedures will be needed. Methods: We pooled samples of nipple aspirate fluid from healthy breasts and breasts with cancer to prepare a control sample. Aliquots of the control sample were used on two spots on each of three IMAC ProteinChip® arrays (Ciphergen Biosystems, Inc.) on 4 successive days to generate 24 SELDI spectra. In 36 subsequent experiments, the control sample was applied to two spots of each ProteinChip array, and the resulting spectra were analyzed to determine how closely they agreed with the original 24 spectra. Results: We describe novel algorithms that (a) locate peaks in unprocessed proteomics spectra and (b) iteratively combine peak detection with baseline correction. These algorithms detected ∼200 peaks per spectrum, 68 of which are detected in all 24 original spectra. The peaks were highly correlated across samples. Moreover, we could explain 80% of the variance, using only six principal components. Using a criterion that rejects a chip if the Mahalanobis distance from both control spectra to the center of the six-dimensional principal component space exceeds the 95% confidence limit threshold, we rejected 5 of the 36 chips. Conclusions: Mahalanobis distance in principal component space provides a method for assessing the reproducibility of proteomics spectra that is robust, effective, easily computed, and statistically sound.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3