Utility of Antinuclear Antibody Screening by Various Methods in a Clinical Laboratory Patient Cohort

Author:

Deng Xiaoli1,Peters Brian2,Ettore Michael W2,Ashworth Judy2,Brunelle Lynn A2,Crowson Cynthia S34,Moder Kevin G4,Snyder Melissa R2

Affiliation:

1. Department of Rheumatology and Immunology, Peking University Third Hospital, Beijing, China

2. Division of Clinical Biochemistry and Immunology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN

3. Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, MN

4. Division of Rheumatology, Department of Medicine, Mayo Clinic, Rochester, MN

Abstract

Abstract Background Antinuclear antibody (ANA)5 testing is routinely performed during evaluation of patients with a suspected connective tissue disease (CTD), yet the question of which method is most appropriate remains controversial. The purpose of this study was to evaluate the clinical utility of ANA testing by an enzyme immunoassay (EIA), an immunofluorescence assay (IFA), and a multiplex immunoassay (MIA) in a routine laboratory population. Methods Samples (n = 1000) were collected from specimens submitted for ANA testing by EIA (Bio-Rad). All samples were subsequently analyzed by IFA (Zeus) and MIA (Bio-Rad). The sample cohort was weighted to represent the routine testing population. Diagnostic information was obtained by chart review. Results For the diagnosis of a CTD, ROC curve analysis demonstrated no significant differences between IFA (area under the curve 0.81) and EIA (0.84) (P = 0.25), with overlay of a single point for the MIA. When normalized to a specificity of approximately 90%, the sensitivities of the MIA, EIA, and IFA were 67%, 67%, and 56%, respectively. By varying the clinical cutoff, the IFA could achieve the highest sensitivity of 94%; however, the corresponding specificity was only 43%. In contrast, a strongly positive EIA had a specificity of 97%, although, at this cutoff, the sensitivity was only 40%. Conclusions Although the overall diagnostic performance of the IFA, EIA, and MIA were not statistically different, the clinical sensitivity and specificity varied dramatically based on the positive/negative cutoff. Knowledge about the performance characteristics of each method will significantly aid in the interpretation of ANA testing.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3