Variability in Microplate Surface Properties and Its Impact on ELISA

Author:

Lilyanna Shera1,Ng Enoch Ming Wei2,Moriguchi Shiho3,Chan Siew Pang1,Kokawa Ryohei4,Huynh So Hung2,Chong P C Jenny1,Ng Yan Xia1,Richards A Mark15,Ng Tuck Wah2,Liew Oi Wah1

Affiliation:

1. Cardiovascular Research Institute, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, National University Health System, Singapore

2. Laboratory for Optics & Applied Mechanics, Department of Mechanical & Aerospace Engineering, Monash University, Clayton, Australia

3. Shimadzu Techno-Research Inc., Kyoto, Japan

4. Global Application Development Center, Shimadzu Corporation, Japan

5. Christchurch Heart Institute, Department of Medicine, University of Otago, Christchurch, New Zealand

Abstract

Abstract Background Microplate-based immunoassays are widely used in clinical and research settings to measure a broad range of biomarkers present in complex matrices. Assay variability within and between microplates can give rise to false-negative and false-positive results leading to incorrect conclusions. To date, the contribution of microplates to this variability remains poorly characterized and described. This study provides new insights into variability in immunoassays attributable to surface characteristics of commercial microplates. Methods Well-to-well assay variation in γ-treated and nontreated 96-well opaque microplates suitable for chemiluminescence assays was determined by use of a validated sandwich ELISA. Microplate surface characteristics were assessed by sessile drop contact angle measurements, scanning electron microscopy, energy dispersive x-ray spectroscopy, and atomic force microscopy. Results All microplate types tested exhibited vendor-specific assay response profiles; and “rogue” plates with very high intraassay variation and deviant mean assay responses were found. Within-plate, location-dependent bias in assay responses and variability in well contact angle were also observed. We demonstrate substantial differences in well-surface properties with putative effects on protein-coating reproducibility and hence consistency in immunoassay responses. A surface “cleaning” effect on manufacturing residues was attributed to γ-irradiation, and treated microplates manifest increased polar functionalities, surface roughness, and assay responses. Conclusions Our data suggest that tighter control of variability in surface roughness, wettability, chemistry, and level of residual contaminants during microplate preparation is warranted to improve consistency of ELISA assay read out.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3