Abstract
A method that improves the accuracy of misorientations determined from Kikuchi patterns is described. It is based on the fact that some parameters of a misorientation calculated from two orientations are more accurate than other parameters. A procedure which eliminates inaccurate elements is devised. It requires at least two foil inclinations. The quality of the approach relies on the possibility to set large sample-to-detector distances and the availability of good spatial resolution of transmission electron microscopy. Achievable accuracy is one order of magnitude better than the accuracy of the standard procedure.
Publisher
International Union of Crystallography (IUCr)
Subject
General Biochemistry, Genetics and Molecular Biology
Cited by
6 articles.
订阅此论文施引文献