Clinical Dosimetric Study of Three Radiotherapy Techniques for Postoperative Breast Cancer: Helical Tomotherapy, IMRT, and 3D-CRT

Author:

Zhou G-X.1,Xu S-P.1,Dai X-K.1,Ju Z-J.1,Gong H-S.1,Xie C-B.1,Yin L-M.1,Yang J.2

Affiliation:

1. Department of Radiation oncology Chinese PLA General Hospital, Beijing 100853, China

2. Department of Radiation Oncology Monmouth Medical Center 300 2nd Avenue Long Branch, NJ 07740

Abstract

This paper is to investigate the dosimetric characteristics of Helical Tomotherapy (HT), step-and-shoot intensity-modulated radiation therapy (SaS-IMRT) and three-dimensional conformal radiation therapy (3D-CRT) for the postoperative breast cancer as well as their dosimetric comparison of the normal tissues. CT images of 10 postoperative patients with early stage breast cancer were transferred into HT, SaS-IMRT and 3D-CRT planning systems respectively after the target region and normal tissues were outlined by the same physician to assure the contour consistency. Each prescribed dose for three different modalities of plans was given to a total of 50 Gy in 25 fractions. Doses and irradiated volumes in heart, lungs, as well as conformity index (CI) and homogeneity index (HI) were evaluated for detailed comparison. All three plans showed appropriate coverage for the prescribed target dose in the dosimetric comparison. The CI in HT and SaS-IMRT as well as 3D-CRT was 0.68 ± 0.12, 0.58 ± 0.08 and 0.40 ± 0.08, respectively. The HI were 1.10 ± 0.03, 1.14 ± 0.02 and 1.17 ± 0.04, which appeared intergroup significant differences (p < 0.05). V5, V10, as well as V20 of the heart were smallest in 3D-CRT than HT and SaS-IMRT. V5 of the ipsilateral lung was the smallest in 3D-CRT than HT and SaS-IMRT (p < 0.05); However, V20 and V30 were smaller in HT and SaS-IMRT than 3D-CRT (p < 0.05). V5 of the contralateral lung was the smallest in 3D-CRT than other groups, with V10~V30 were basically similar in numeric values with not obvious discrepancy. Comparing with SaS-IMRT and 3D-CRT, HT technique in treating breast cancer had the best conformity and homogeneity index as well as steepest dose gradient due to its highly modulated beamlets with rotational technique. The heart volume irradiated was the smallest in conventional 3D-CRT, with SaS-IMRT was the largest among the three techniques, as expected. The volume of the contralateral lung irradiated was the smallest in 3D-CRT than other groups. V5 of the ipsilateral lung was the smallest in 3D-CRT than other two groups. V10~V30 in HT and SaS-IMRT were similar and better than 3D-CRT dosimetrically. We conclude that HT technique had advantages over SaS-IMRT and 3D-CRT based on the dosimetric comparison in this study, especially in the high dose region of ipsilateral lung, target homogeneity and dose uniformity.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3