A Computed Tomography-Based Assessment of the Anatomical Parameters Concerning S2-Alar Iliac Screw Insertion Using “Safe Trajectory Method” in Indian Population

Author:

Kaul Rahul,Goswami Bharat,Kumar Khemendra,Jeyaraman Madhan,Sangondimath Gururaj,Chhabra HS

Abstract

Study Design: A retrospective computed tomography (CT)-based radiological analysis.Purpose: To obtain CT-based morphometric data for the S2 alar iliac (S2AI) screw in the Indian population presenting to School of Medical Sciences and Research, Greater Noida, we used the concept of “safe trajectory” by Pontes and his colleagues in a recent study.Overview of Literature: Although previous CT-based morphometric studies on the S2AI screw have been published for a variety of ethnic groups, morphometric data specifically for the Indian population are scarce.Methods: We used the three-dimensional multiplanar reformatting software to conduct a retrospective CT analysis of 112 consecutive patients who met our exclusion criteria for various abdominal and pelvic pathologies. CT imaging planes were rotated between the S1 and S2 foramen until they matched the ideal S2AI screw trajectory, which was represented by the longest and widest iliac osseous channel observed in the axial CT section. Following the concept of a safe trajectory, S2AI screw morphometric parameters were measured on both sides of the pelvis using corresponding axial and sagittal CT images.Results: In the sagittal and transverse planes on both sides of the pelvis, females had significantly higher screw trajectory angulation than males (<i>p</i><0.001). On both sides of the pelvis, males had significantly greater iliac width, maximum screw trajectory length, and intrascrotal length than females (<i>p</i><0.001). On both sides of the pelvis, the S2AI screw entry point in females was significantly deeper than in males from the skin margin (<i>p</i><0.001).Conclusions: Based on our methodology, we discovered that the S2AI screw trajectory is significantly more caudal and lateral in females, the maximum screw length is sufficient for use in clinical practice regardless of gender, and that 8.5 mm or even larger screw diameters are feasible in the majority of the Indian population.

Publisher

Asian Spine Journal (ASJ)

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3