Digital anatomical study and clinical application of the ideal S2 alar-lliac screw trajectory

Author:

Zhao Yonghui,Ma Yulong,Wang Qiyang,Luo Haotian,Liu Jie,Lu Sheng

Abstract

Abstract Background To investigate the ideal trajectory for the S2AI screw and to clinically validate its safety feasibility. Methods The 3D model was reconstructed from CT data of the pelvis of 30 selected adults, and the 3D coordinate system was established with the first sacral superior endplate as the horizontal plane. A set of cutting planes was made at 3 mm intervals in the coronal plane, and the cross-sectional internal tangent circles were divided in the target area. Using the linear fitting function, the axis of 90 mm length was calculated by the least squares method for each inner tangent circle center. The diameter of the axis is gradually increased until the first contact with the cortex, and the cylindrical model is the ideal screw trajectory. The intersection of the axis and the dorsal cortex is the screw placement point, which is located by Horizon Distance (HD) and Vertical Distance (VD); the diameter of the screw trajectory (d) is the diameter of the cylindrical model; the direction of the screw trajectory is determined by Sagittal Angle (SA) and Transverse Angle (TA). The screw trajectory orientation is determined by Sagittal Angle (SA) and Transverse Angle (TA). Based on the ideal screw trajectory, the 3D printed surgical guide and freehand techniques were used to verify its safety feasibility, respectively. Results The screw placement points [HD (4.7 ± 1.0) mm, VD (19.7 ± 1.9) mm], screw placement directions [SA (31.3°±2.3°), TA (42.4°±2.3°)], and screw dimensions for the ideal screw trajectory of the S2AI were combined for analysis. (L is 90 mm, d is 13.2 ± 1.4 mm). The S2AI screw superiority rate [96.6% (56/58)] and reasonable rate [100%] were higher in the guide group than in the freehand group [90.0% (63/70), 97.1% (68/70)], but the differences were not statistically significant (P > 0.05). Although screws invaded the cortex in both groups, there were no associated adverse events in either group. Conclusion The S2AI screw-based ideal trajectory placement is a safe, feasible and accurate method of screw placement.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3