Comparison of [99mTc]HMPAO SPECT with [18F]Fluoromethane PET in Cerebrovascular Disease

Author:

Heiss W.-D.,Herholz K.,Podreka I.1,Neubauer I.,Pietrzyk U.

Affiliation:

1. Neurologische Universitäts Klinik Wien, Wien, Austria

Abstract

Positron emission tomography (PET) of [18F]fluoromethane (FM) and single-photon emission tomography (SPECT) of [99mTc]hexamethylpropyleneamine oxime (HMPAO) were performed under identical conditions within 2 h in 22 patients suffering from cerebrovascular disease (8 ischemic infarction, 2 intracerebral hemorrhages, 7 transient ischemic attacks, and 5 multi-infarct syndrome). While gross pathological changes could be seen in the images of either procedure, focal abnormalities corresponding to transient ischemic deficits or to lesions in multi-infarct syndrome and areas of functional deactivation were sometimes missed on SPECT images. Overall, HMPAO SPECT images showed less contrast between high and low activity regions than the FM PET images, and differences between lesions and contralateral regions were less pronounced (6.4 vs 13.3% difference). Regional cerebral blood flow (rCBF) was calculated from FM PET studies in 14 large territorial regions and the pathological lesion, and the regional values relative to mean flow were compared to the relative HMPAO uptake in an identical set of regions defined on the SPECT images. Among individual patients, the Spearman rank-correlation coefficient between relative rCBF and HMPAO uptake varied between 0.48 and 0.89, with a mean of 0.70. While an underestimation of high flow with SPECT—which was demonstrated in a curvilinear relationship between all relative regional PET and SPECT values—could be corrected by linearization taking into account HMPAO efflux from the brain before metabolic trapping, correspondence of SPECT data with PET rCBF values was not improved since this procedure also increased the variance in high flow areas. In the cerebellum, however, a high HMPAO uptake in SPECT always overestimated CBF in relation to forebrain values; this finding might be due to high capillary density in the cerebellum. The differences observed between SPECT and PET data may be explained by technical and physical properties of the methods and by the incomplete first-pass extraction of HMPAO. Additionally, HMPAO or its metabolites may leak through a damaged blood–brain barrier (as observed in one infarct and in the surrounding of hemorrhages), impairing the contrast between lesion and normal tissue. The presented data indicate that the quantification of rCBF by HMPAO SPECT is limited.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Neurology

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Classification of Ischemic Stroke;Stroke;2022

2. Amyloid Imaging With 11C-PIB in Patients With Cognitive Impairment in a Clinical Setting;Clinical Nuclear Medicine;2016-01

3. Classification of Ischemic Stroke;Stroke;2016

4. La neuroimagen molecular en las demencias degenerativas;Revista Española de Medicina Nuclear e Imagen Molecular;2013-09

5. Molecular neuroimaging in degenerative dementias;Revista Española de Medicina Nuclear e Imagen Molecular (English Edition);2013-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3