Quantitative Measurements of Cerebral Blood Flow Using SPECT and [99mTc]-d,l-HM-PAO Compared to Xenon-133

Author:

Andersen Allan R.,Friberg Hans H.,Schmidt Jes F.1,Hasselbalch Steen G.

Affiliation:

1. Department of Neurosurgery, Rigshospitalet, Copenhagen, Denmark

Abstract

The uptake and retention in a 2 cm thick brain section was recorded serially by SPECT after i.v. injection of [99mTc]– d,l-HM-PAO (HM-PAO). In 16 patients, the fraction of the administered dose retained by the brain was 5.2 ± 1%, showing a peak after 40–50s, then decreasing by 10% within the first 10 min and then by only 0.4% per hour. The image contrast was measured in each patient as the regional hemispheric asymmetry difference in percent of the highest value of the two regions. It deceased from 31% at 30–40 s to 25% at 10 min. At 24 h, a value of 19% was reached. Using the images obtained at 10 min after injection, a region to region comparison of the original and corrected HM-PAO images to the xenon-133 regional cerebral blood flow (rCBF) images was performed. Forty-four patients with stroke, epilepsy, dementia, basal ganglia disease, and tumors and control subjects were included in this comparison. The algorithm proposed by Lassen et al. was used to correct the original images for back diffusion of tracer (brain to blood); a good correlation very close to the line of identity between the corrected HM-PAO and xenon-133 data was obtained when using a conversion/clearance ratio of 1.5 and when the noninvolved hemisphere was used as a reference region ( r = 0.86, p < 0.0001). Serial arterial and cerebral venous blood sampling was performed over 10 min following i.v. injection of HM-PAO in six patients. An overall brain retention fraction of 0.37 ± 0.03 (mean ± SEM) was calculated from the data. An average CBF of 0.62 ± 0.12 ml/g/min was determined on the basis of the Fick principle; this compared to a value of 0.59 ± 0.09 ml/g/min (mean ± SEM) measured by the xenon-133 inhalation method. The two sets of CBF values correlated linearly with a correlation coefficient of 0.97 ( p < 0.01). Inserting the average CBF value for the hemisphere as measured by the Fick principle into the algorithm described by Lassen et al. yields absolute rCBF values (ml/g/min) directly from the corrected HM-PAO images. We conclude that the xenon-133 inhalation method and [99mTc]– d,l-HM-PAO may supplement each other for SPECT studies of rCBF: xenon-133 inhalation for easy, repeatable, and quantitative measurements and [99mTc]– d,l-HM-PAO for high resolution static imaging in relative or absolute flow units.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical),Neurology

Cited by 112 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3