Evaluating the accuracy of hand models obtained from two 3D scanning techniques

Author:

Yu Fang,Zeng Lei,Pan Ding,Sui Xinlei,Tang Juyu

Abstract

AbstractThe aim of this study was to identify an efficient approach for 3D imaging of hand. The 3D photographs of hand were taken with Gemini structured-light scanning system (SL scanning) and CT scanning. The 3D photographs, average time of scanning and reconstruction were compared between these two indirect techniques. The reliability, reproducibility and accuracy were evaluated in these two indirect techniques and the direct measurement (DM). Statistical differences in the measurements were assessed by 99% probability, with clinical significance at > 0.5 mm. The Gemini structured-light scanning system established a complete and smooth 3D hand photograph with shorter scanning and reconstruction time. Reproducibility of CT scanning and SL scanning methods was better (P < 0.01, both) than the DM, but did not differ significantly from each other (P = 0.462). Of the 19 (31.58%) measurements obtained, 6 showed significant differences (P < 0.01). Significant differences were observed more often for circumference dimensions (5/9, 55.56%) than for length dimensions (1/10, 10%). Mean absolute error (AE) of the 10 subjects was very low for 3D CT (0.29 ± 0.10 mm) and SL scanning (0.30 ± 0.11 mm). Absolute percentage error (APE) was 4.69 ± 2.33% and 4.88 ± 2.22% for 3D CT and SL scanning, respectively. AE for the PIP circumference between the 3rd finger (0.58 mm) and 4th finger (0.53 mm) scan was > 0.5 mm, indicating significant difference between DM and CT scanning at the level of 99% probability. In this study, the Gemini structured-light scanning system not only successfully established a complete and smooth 3D hand photograph, but also shortened the scanning and reconstruction time. Compared to the DM, measurements obtained using the two indirect techniques did not show any statistically or clinically insignificant difference in the values of the remaining 17 of 19 measurements (89.47%). Therefore, either of the two alternative techniques could be used instead of the direct measurement method.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Hand anthropometrics from radiograms of Italian women: A population-specific ergonomic design procedure;Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science;2024-07-25

2. mmHand: 3D Hand Pose Estimation Leveraging mmWave Signals;2024 IEEE 44th International Conference on Distributed Computing Systems (ICDCS);2024-07-23

3. Three-dimensional imaging of the forearm and hand: A comparison between two 3D imaging systems;PLOS Digital Health;2024-04-18

4. Understanding Error Patterns: An Analysis of Alignment Errors in Rigid 3D Body Scans;Journal of Imaging;2023-11-21

5. Effect of Three-Dimensional (3D) Scanning Factors on Minimizing the Scanning Errors Using a White LED Light 3D Scanner;Applied Sciences;2023-03-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3