Converse Magnetoelectric Composite Resonator for Sensing Small Magnetic Fields

Author:

Hayes P.,Jovičević Klug M.ORCID,Toxværd S.,Durdaut P.ORCID,Schell V.,Teplyuk A.,Burdin D.,Winkler A.,Weser R.,Fetisov Y.,Höft M.ORCID,Knöchel R.,McCord J.,Quandt E.

Abstract

Abstract Magnetoelectric (ME) thin film composites consisting of sputtered piezoelectric (PE) and magnetostrictive (MS) layers enable for measurements of magnetic fields passively, i.e. an AC magnetic field directly generates an ME voltage by mechanical coupling of the MS deformation to the PE phase. In order to achieve high field sensitivities a magnetic bias field is necessary to operate at the maximum piezomagnetic coefficient of the MS phase, harnessing mechanical resonances further enhances this direct ME effect size. Despite being able to detect very small AC field amplitudes, exploiting mechanical resonances directly, implies a limitation to available signal bandwidth along with the inherent inability to detect DC or very low frequency magnetic fields. The presented work demonstrates converse ME modulation of thin film Si cantilever composites of mesoscopic dimensions (25 mm × 2.45 mm × 0.35 mm), employing piezoelectric AlN and magnetostrictive FeCoSiB films of 2 µm thickness each. A high frequency mechanical resonance at about 515 kHz leads to strong induced voltages in a surrounding pickup coil with matched self-resonance, leading to field sensitivities up to 64 kV/T. A DC limit of detection of 210 pT/Hz1/2 as well as about 70 pT/Hz1/2 at 10 Hz, without the need for a magnetic bias field, pave the way towards biomagnetic applications.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Feasibility of magnetomyography with optically pumped magnetometers in a mobile magnetic shield;Scientific Reports;2024-08-16

2. Magnetoelastic Constraint on Sensor-Intrinsic Noise;2024 IEEE International Magnetic Conference - Short papers (INTERMAG Short papers);2024-05-05

3. Recent Advances in Modeling AE-Effect Magnetic Field Sensors;2024 IEEE International Magnetic Conference - Short papers (INTERMAG Short papers);2024-05-05

4. Low-noise inverse magnetoelectric magnetic field sensor;Applied Physics Letters;2024-04-22

5. Nonlinear magnetoelectric effects in layered multiferroic composites;Journal of Applied Physics;2024-01-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3