The role of implants and implant prostheses on the accuracy and artifacts of cone-beam computed tomography: an in-vitro study

Author:

Gurjar Balwant Singh,Sharma Vineet,Paliwal Jyoti,Kalla Rajani,Meena Kamal Kumar,Tahir Mohammed

Abstract

AbstractTo assess the accuracy of CBCT in implant-supported prostheses and to evaluate metal artifacts with and without implants or implant prostheses. Accuracy and artifacts were assessed in the dried mandible at three points on the buccal and lingual cortical plates on the mandible's body near the crest and the base. On the buccal cortical plate, these points were labelled as A, B and C near the crest and D, E and F near the base of the body of the mandible. Similarly, points a to f were marked on the lingual cortical plate corresponding to points A to F. The study had two control groups, C0 for physical linear measurement (PLM) and C1 for radiographic linear measurement (RLM) and artifact assessment. There were seven test groups, TG 1 to 7, progressing from a single implant to implant full-arch prosthesis. For accuracy assessment, PLM was compared to RLM. CBCT artifacts were investigated in images integrated at 0.25 mm, 10 mm, and 20 mm at regions of interest on concentric circles at different intersecting angles by comparing grayscale values at C1 and TG1 to 7. The data were collected and statistically analyzed. A significant difference was observed between C0 and C1, and RLM in test groups at the superior axial plane. Similarly, PLM and test RLM in the sagittal plane at A-B, B-C, and D-E were statistically significant. A significant difference between PLM and RLM was also observed in the vertical plane at A-D, B-E, and C-F. Quantification of CBCT artifacts in the presence of implants or prostheses revealed that full-arch prostheses had the highest mean grayscale value, whereas single implants with a prosthesis had the lowest. The mean grayscale change was greatest around the implant and implant prosthesis. The mean grayscale value was maximum at 20 mm voxel integration scales (VIS) and lowest at 0.25 mm. CBCT is a clinically reliable device. Metal in implants or implant-supported prostheses prevents true assessment of the peri-implant area; therefore, lower VIS is suggested in the presence of implants or implant prostheses.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3