The Precision of All-on-Four Implant Position Recorded from Three Different CBCT Machines

Author:

Alsulimani Osamah1ORCID,Alhaddad Abdulrahman2,Altassan Mosa2,Bukhari Asmaa2,Munshi Lulu3,Sabir Ghalia3

Affiliation:

1. Department of Oral Diagnostic Sciences, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia

2. Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia

3. Internship program, Faculty of Dentistry King Abdulaziz University, Jeddah, Saudi Arabia

Abstract

Abstract Objective To investigate the dimensional discrepancy and degree of deviation of All-on-Four implant position between different cone-beam computed tomography (CBCT) machines. Materials and Methods Four implants (4.5 × 10 mm Superline II, Dentium, South Korea) were placed in an All-on-Four style in an artificial mandible. The jaw was radiated 30 times using three different CBCT machines (Rainbow CT, Dentium; Veraview X800, Morita, Japan; Planmeca Viso G3, Planmeca OY, Finland). A total of 30 Digital Imaging and Communications in Medicine (DICOM) files were exported, n = 10. All-on-Four implants from each DICOM file were segmented and exported as an STL file (three-dimensional image) using Blue Sky Plan software (version 4.12.13/Blue Sky Bio, United States). All-on-Four implant zone dimensions (X, Y, and Z axes) and the total degree of deviation between All-on-Four implants per CBCT machine were measured using Autodesk Meshmixer software (version 3.5.474/California, United States). The data distribution's normality and variances' equality were tested with Shapiro–Wilk's and Levene's tests, respectively (p-value < 0.05). Data were analyzed using Brown–Forsythe one-way analysis of variance and Tamhane's post hoc tests to compare the differences between the groups (p-value <0.05). Results The respective X, Y, and Z mean dimensions of the All-on-Four implant zone were: Dentium (34.95, 14.71, and 9.97); Morita (34.88, 14.74, and 10.56); and Planmeca (34.73, 15.15, and 12.33). Significant differences between CBCT machines were found in all axes (p-value < 0.05); however, the Z-axis had the most differences. Notably, Planmeca exhibited the highest standard deviation (SD) in all axes (0.16–0.35), exhibiting the lowest consistency in the CBCT machines' readings. The Dentium exhibited the lowest deviation in the implant position, with the lowest SD (0.61). A significant difference in the total degree of deviation was spotted when only Morita was included in the comparison (p-value < 0.05). Conclusion This study's findings are of significant importance as they reveal that the implant position recorded from the CBCT machines was most discrepant in the buccolingual dimension (Z-axis). Planmeca exhibited the least implant-dimensional accuracy of the CBCT machines, while Dentium exhibited the highest implant position accuracy. These results could significantly impact the choice of CBCT machine for implant placement, especially since an accurate CBCT image is crucial for digital implant planning.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3