Author:
Godavarthi V.,Dhivyaraja K.,Sujith R. I.,Panchagnula M. V.
Abstract
Abstract
Atomizers find applications in diverse fields such as agriculture, pharmaceutics and combustion. Among the most commonly found atomizer classes of designs are pressure swirl, airblast and ultrasonic atomizers. However, it has thus far not been possible to identify the class of an atomizer from spray characteristics. We perform multifractal detrended fluctuation analysis on the droplet inter-arrival times, diameters and axial velocities of pressure swirl, airblast and ultrasonic nebulizer sprays to quantify the differences in complexity in the respective signals. We show that the width of the multifractal spectrum of the signals of droplet diameters and the inter-arrival times, measured at the edge of the spray are robust atomizer identifiers. Further, we show the presence of correlations among the droplet diameters which are otherwise considered as random or derived from a log-normal distribution. This study can be further generalized to classify fluid mechanical systems or biological sprays using an appropriately chosen single point measurement in the flow field.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献