Abstract
Abstract
Background
Nebulized lidocaine reduced stress response for endotracheal intubation. However, the impact of novel lidocaine aerosol inhalation for intubation by ultrasonic atomizer was unclear. Hence, we designed aerosol inhalation of lidocaine by ultrasonic atomizer, to seek whether the dosage of sufentanil for intubation could be less or not.
Methods
Intravenous injection of sufentanil started at 0.5 μg/kg, and sufentanil dosage was increased/decreased (step-size 0.05 μg/kg for sufentanil) using Dixon’s up and down method. The observation was terminated after 8 reflexes.
Results
The EC50 and EC95 of sufentanil with lidocaine by ultrasonic atomizer for intubation were found to be 0.232 μg/kg (95% CI: 0.187–0.270 μg/kg) and 0.447 μg/kg (95% CI: 0.364–0.703 μg/kg). 55.88% out of 34 patients showed hemodynamic index change < 20% of baseline during intubation.
Conclusion
Aerosol inhalation of lidocaine by ultrasonic atomizer reduced the dosage of sufentanil for endotracheal intubation. Lidocaine inhalation by ultrasonic atomizer for airway anesthesia with minimal dosage of sufentanil could be recommended, particularly in patients who need more stable hemodynamic changes or spontaneous respiration.
Trial registration
Chinese Registry of Central Trial, ChiCTR-IOR-17014198.
Registered 28 December 2017.
Funder
National Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献