Abstract
AbstractVisual acuity can be measured in many different ways, including with letters and Vernier offsets. Prior psychophysical work has suggested that the two acuities are strongly linked given that they both depend strongly on retinal eccentricity and both are similarly affected in amblyopia. Here we used high-density EEG recordings to ask whether the underlying neural sources are common as suggested by the psychophysics or distinct. To measure visual acuity for letters, we recorded evoked potentials to 3 Hz alternations between intact and scrambled text comprised of letters of varying size. To measure visual acuity for Vernier offsets, we recorded evoked potentials to 3 Hz alternations between bar gratings with and without a set of Vernier offsets. Both alternation types elicited robust activity at the 3 Hz stimulus frequency that scaled in amplitude with both letter and offset size, starting near threshold. Letter and Vernier offset responses differed in both their scalp topography and temporal dynamics. The earliest evoked responses to letters occurred on lateral occipital visual areas, predominantly over the left hemisphere. Later responses were measured at electrodes over early visual cortex, suggesting that letter structure is first extracted in second-tier extra-striate areas and that responses over early visual areas are due to feedback. Responses to Vernier offsets, by contrast, occurred first at medial occipital electrodes, with responses at later time-points being more broadly distributed—consistent with feedforward pathway mediation. The previously observed commonalities between letter and Vernier acuity may be due to common bottlenecks in early visual cortex but not because the two tasks are subserved by a common network of visual areas.
Funder
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (Swiss National Science Foundation
anonymous donor
Publisher
Springer Science and Business Media LLC
Reference94 articles.
1. Snellen, H. Letterproeven tot Bepaling der Gezichtsscherpte (1862).
2. Landolt, E. In Graefe-Saemisch Handbuch (1904).
3. Bailey, I. L. & Lovie, J. E. New design principles for visual acuity letter charts. Am. J. Optom Physiol. Opt. 53, 740–745 (1976).
4. Colenbrander, G. The historical evolution of visual acuity measurement. Visual Impair. Res. 10, 57–66 (2008).
5. Gstalder, R. J. & Green, D. G. Laser interferometric acuity in amblyopia. J. Pediatr. Ophthal. 8, 251–256 (1965).
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献