Author:
Y. A. Alanazi Tahani,Adel Pashameah Rami,Y. Binsaleh Ammena,A. Mohamed Mahmoud,A. Ahmed Hoda,F. Nassar Hossam
Abstract
AbstractA precise, Eco-friendly, and highly sensitive RP-HPLC method was employed using quality-by-design principles to concurrently identify cephalexin and cefixime residues in the manufacturing machines using a hypersil BDS C18 column (250 × 4.6 mm, 5 μm) at wavelength 254 nm. The Box–Behnken design was applied to obtain the best chromatographic conditions with the fewest possible trials. Three independent factors viz organic composition, flow rate, and pH were used to assess their effects on the responses' resolution and retention time. Overlay plot and desirability functions were implemented to predict responses of the high resolution and relatively short retention time using a mobile phase composed of acidic water: acetonitrile (85:15, v/v) at pH 4.5 adjusted by phosphoric acid with a flow rate of 2.0 mL/min. The spectral overlapping of the drugs was successfully resolved by the mean centering ratio (MCR) spectra approach at 261 nm and 298 nm for cephalexin and cefixime, respectively. Good linearity results were obtained for the suggested HPLC and MCR methods over the concentration range of (0.05–10 ppm) and (5–30 ppm) with a detection limit of 0.003, 0.004, 0.26, and 0.23 ppm, and quantitation limits of 0.008, 0.013, 0.79, and 0.68 ppm for cephalexin and cefixime, respectively, with a correlation coefficient of ≥ 0.9998 and good swab recovery results of 99–99.5%. A process capability index was accomplished for chemical and micro results, illustrating that both are extremely capable. The suggested method was effectively validated using ICH recommendations.
Publisher
Springer Science and Business Media LLC
Reference62 articles.
1. Armenta, S., Garrigues, S. & de la Guardia, M. Green analytical chemistry. TraC Trends Anal. Chem. 27, 497–511 (2008).
2. Sajid, M. & Płotka-Wasylka, J. Green analytical chemistry metrics: A review. Talanta 238, 123046 (2022).
3. WHO good manufacturing practices: main principles for pharmaceutical products. In: WHO Expert Committee on Specifications for Pharmaceutical Preparations: forty-eighth report. Geneva: World Health Organization. Annex 3 (WHO Technical Report Series) 986. http://apps.who.int/medicinedocs/documents/s21467en/s21467en (2014).
4. Hassouna, M. E. M. & Mohamed, M. A. Efficient HPLC method for determination of cephalosporin residues on spiked stainless-steel plates and human plasma: Application of a worst-case product for Cosa® CIP. Int. J. Environ. Anal. Chem. 100, 82–98 (2020).
5. FDA. Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients Guidance for Industry. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/q7-good-manufacturing-practice-guidance-active-pharmaceutical-ingredients-guidance-industry (2016).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献