Abstract
AbstractAn abnormal elevation in pressure is a serious complication involving the extracorporeal circulation circuit. Clot formation might be associated with this complication, but the precise mechanism of an abnormal elevation in pressure has not been identified. We investigated sufficient conditions for in-circuit elevation in pressure using an ex vivo re-circulation circuit with porcine blood. Specifically, we investigated the effect of blood conditions, the type of anticoagulation, and pro-inflammatory stimulation on in-circuit pressure. We also examined the cause of an abnormal elevation of in-circuit pressure by specifically degrading DNA, RNA, or protein components of an obstructed filter and by using immunofluorescent techniques. Neither a change in temperature nor change in pH in the blood increased in-circuit pressure. In contrast, long-term storage of blood, pro-inflammatory stimulation by phorbol myristate acetate, and heparin administration significantly increased in-circuit pressure. Abnormal in-circuit elevation in pressure was associated with deposition of extracellular DNA on the outlet surface of the filter. Administration of DNase resulted in a rapid decline of in-circuit pressure. In an ex vivo re-circulation circuit system, extracellular DNA deposition on the filter is responsible for an abnormal in-circuit elevation in pressure. Senescent leukocytes, stimulated leukocytes, and heparin exposure are associated with extracellular DNA deposition.
Funder
This work was supported by grants from JMS Co., Ltd.
Publisher
Springer Science and Business Media LLC
Reference31 articles.
1. Blombäck, M. et al. Pathologic fibrin formation and cold-induced clotting of membrane oxygenators during cardiopulmonary bypass. J. Cardiothorac Vasc Anesth. 9(1), 34–43 (1995).
2. Wahba, A., Philipp, A., Behr, R. & Birnbaum, D. E. Heparin-coated equipment reduces the risk of oxygenator failure. Ann thorac surg. 65(5), 1310–2 (1998).
3. Myers, G. J. et al. A multicenter investigation into the occurrence of high-pressure excursions. J. Extra Corpor technol. 35(2), 127–32 (2003).
4. Charriere, J. M. et al. Survey: retrospective survey of monitoring/safety devices and incidents of cardiopulmonary bypass for cardiac surgery in France. J. Extra Corpor technol. 39(3), 142–57; discussion 58–9 (2007).
5. Mejak, B. L., Stammers, A., Rauch, E., Vang, S. & Viessman, T. A retrospective study on perfusion incidents and safety devices. Perfusion. 15(1), 51–61 (2000).