Electrophysiological and fundoscopic detection of intracranial hypertension in craniosynostosis

Author:

Rufai Sohaib R.,Marmoy Oliver R.ORCID,Thompson Dorothy A.ORCID,van de Lande Lara S.,Breakey R. William,Bunce CateyORCID,Panteli Vasiliki,Schwiebert Kemmy,Mohamed Shafquet,Proudlock Frank A.,Gottlob Irene,Dunaway David J.,Hayward Richard,Bowman RichardORCID,Jeelani Noor ul OwaseORCID

Abstract

Abstract Aims To assess the diagnostic accuracy of fundoscopy and visual evoked potentials (VEPs) in detecting intracranial hypertension (IH) in patients with craniosynostosis undergoing spring-assisted posterior vault expansion (sPVE). Methods Children with craniosynostosis undergoing sPVE and 48-hour intracranial pressure (ICP) monitoring were included in this single-centre, retrospective, diagnostic accuracy study. Data for ICP, fundoscopy and VEPs were analysed. Primary outcome measures were papilloedema on fundoscopy, VEP assessments and IH, defined as mean ICP > 20 mmHg. Diagnostic indices were calculated for fundoscopy and VEPs against IH. Secondary outcome measures included final visual outcomes. Results Fundoscopic examinations were available for 35 children and isolated VEPs for 30 children, 22 of whom had at least three serial VEPs. Sensitivity was 32.1% for fundoscopy (95% confidence intervals [CI]: 15.9–52.4) and 58.3% for isolated VEPs (95% CI 36.6–77.9). Specificity for IH was 100% for fundoscopy (95% CI: 59.0–100) and 83.3% for isolated VEPs (95% CI: 35.9–99.6). Where longitudinal deterioration was suspected from some prVEPs but not corroborated by all, sensitivity increased to 70.6% (95% CI: 44.0–89.7), while specificity decreased to 60% (95% CI: 14.7–94.7). Where longitudinal deterioration was clinically significant, sensitivity decreased to 47.1% (23.0–72.2) and specificity increased to 100% (47.8–100). Median final BCVA was 0.24 logMAR (n = 36). UK driving standard BCVA was achieved by 26 patients (72.2%), defined as ≥0.30 logMAR in the better eye. Conclusion Papilloedema present on fundoscopy reliably indicated IH, but its absence did not exclude IH. VEP testing boosted sensitivity at the expense of specificity, depending on method of analysis.

Funder

DH | National Institute for Health Research

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP