TRANSLAMINAR VERSUS PEDICLE SCREW FIXATION OF C2: COMPARISON OF SURGICAL MORBIDITY AND ACCURACY OF 313 CONSECUTIVE SCREWS

Author:

Parker Scott L.1,McGirt Matthew J.1,Garcés-Ambrossi Giannina L.1,Mehta Vivek A.1,Sciubba Daniel M.1,Witham Timothy F.1,Gokaslan Ziya L.1,Wolinksy Jean-Paul1

Affiliation:

1. Department of Neurosurgery, The Johns Hopkins University School of Medicine, Johns Hopkins Spinal Column Biomechanics and Surgical Outcomes Laboratory, Baltimore, Maryland

Abstract

Abstract OBJECTIVE C2 translaminar (TL) screws rigidly capture the posterior elements of C2, avoid risk of vertebral artery injury, and are less technically demanding than C2 pedicle (PD) screws. However, a C2-TL screw breach places the spinal cord at risk, and the durability of C2-TL screws remains unknown. It is unclear if TL versus PD screw fixation of C2 is truly associated with less operative morbidity, greater accuracy of screw placement, or equivalent durability. METHODS We retrospectively reviewed the records of 167 consecutive patients undergoing posterior cervical fusion with either PD or TL screw fixation of C2. Perioperative morbidity, breach of the C2 lamina or pedicle on postoperative computed tomographic scans, and rates of operative revision were compared between PD and TL screw constructs in axial (C1–C2 or C1–C3) and subaxial (C2 and caudal) cervical fusions. RESULTS In total, 152 C2-TL screws and 161 C2-PD screws were placed in 167 patients. Thirty-one (19%) cases of axial cervical fusion (C1–C2 or C1–C3) were performed (mean age, 63.8 ± 20.6 years) with either C2-TL (16 [52%]) or C2-PD (15 [48%]) screw fixation. One hundred thirty-six (81%) cases of subaxial cervical fusion (C2-caudal) were performed (mean age, 57.9 ± 14.7 years) with either C2-TL (66 [49%]) or C2-PD (70 [51%]) screw fixation. For both axial and subaxial cervical fusions, baseline patient characteristics and all measures of perioperative morbidity were similar between C2-TL and C2-PD screw cohorts. In total, 11 (7%) PD screws breached the pedicle (0 requiring acute revision) versus only 2 (1.3%) TL screws that breached the C2 lamina (1 requiring acute revision) (P = 0.018). By 1 year postoperatively, pseudoarthrosis or screw pullout requiring reoperation was required in 4 (6.1%) patients with C2-TL screws versus 0 (0%) patients with PD screws (P < 0.05 for subaxial constructs). No cases of C2-TL or C2-PD axial fusion required reoperation or screw pullout or pseudoarthrosis. CONCLUSION In our experience, radiographic breach of C2 pedicle screws occurred more frequently than C2 laminar screw breach. However, this was not associated with an increase in morbidity. By 12 months postoperatively, C2-TL screws were associated with a greater incidence of operative revision when used in subaxial constructs but similarly effective for axial cervical constructs. The 1-year durability of C2-TL screws might be inferior to C2 pedicle screws for subaxial fusions, but equally effective for axial cervical fusions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3