Biomechanical Comparison of Facet Versus Laminar C2 Screws

Author:

Meynard Alexandre12,Fréchède Bertrand2,Pommier Benjamin1,Mitton David2,Barrey Cédric13

Affiliation:

1. Spine Surgery Unit, Hôpital Neurologique Pierre Wertheimer, Hospices Civils de Lyon, and University Claude Bernard of Lyon 1, Bron, France;

2. LBMC UMR T 9406, Univ Lyon, Univ Claude Bernard Lyon 1, Univ Gustave Eiffel, Lyon, France;

3. Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, Paris, France

Abstract

BACKGROUND: Transpedicular or transisthmic screws for C2 instrumentation represent the gold standard; however, the anatomy is not always compatible (hypoplastic pedicles, procidentia of the vertebral artery). Laminar screws (LS) have been proposed as a rescue technique and recently, bicortical facet screws (FS). To date, the biomechanical property of FS remains unknown. OBJECTIVE: To compare the pull-out resistance of bicortical facet (FS) vs laminar (LS) C2 screws. METHODS: Thirty-two human cadaveric C2 vertebrae were screened by CT scan imaging and dual x-ray absorptiometry before receiving both techniques and were randomized according to side and sequence (FS or LS first). Screw positioning was validated using 2-dimensional x-rays. Sixty-four mechanical tests were performed using pure tensile loading along the axis of the screws until pull-out. Mean pull-out strengths were compared using paired tests, multivariate and survival analysis (Kaplan-Meier curves). RESULTS: The morphometric data were consistent with previous studies. Over 64 tests, the mean pull-out strength of LS (707 ± 467 N) was significantly higher than that of FS (390 ± 230 N) (P = .0004). Bone mineral density was weakly correlated with pull-out strength (r = 0.42 for FS and r = 0.3 for LS). Both techniques were mechanically equivalent for vertebrae in which intralaminar cortical grip was not achievable for LS. The mean pull-out strength for LS with laminar cortical grip (1071 ± 395 N) was significantly higher than that of LS without (423 ± 291 N) (P < .0001). CONCLUSION: Our results suggest that bicortical FS of C2 offer less mechanical resistance than LS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3