Accuracy of Laser Placement With Frameless Stereotaxy in Magnetic Resonance-Guided Laser-Induced Thermal Therapy

Author:

Attaar Sakina J1,Patel Nitesh V1,Hargreaves Eric1,Keller Irwin A2,Danish Shabbar F1

Affiliation:

1. Division of Neurosurgery, Rutgers, Robert Wood Johnson Medical School, New Brunswick, New Jersey

2. Department of Radiology, Rutgers, Robert Wood Johnson Medical School, New Brunswick, New Jersey

Abstract

Abstract BACKGROUND As magnetic resonance-guided laser-induced thermal therapy (MRgLITT) becomes more accepted, there needs to be an evaluation of the techniques required to achieve accurate laser placement. OBJECTIVE To report our experience with frameless stereotaxy and the ability to achieve accurate laser placements. We also evaluate the variables associated with proper placement. METHODS We performed a retrospective analysis from 3 years of MRgLITT. Demographics and operational parameters, including trajectory length, target alignment error, registration error, and radial error were recorded and compared. Blinded review was used for completeness of ablation. RESULTS In the study, 90 laser placements were evaluated for 72 cases. Trajectory length and target alignment error was 95.3 ± 26.0 mm and 0.7 ± 0.3 mm, respectively. Significant differences existed in registration error between 4 (0.6 ± 0.3 mm) and 5 (0.5 ± 0.2 mm) skull pins (P = .04), but no significant decreases in registration error as additional skull pins were registered. Fifteen laser placements resulted in subtotal ablations. The overall radial error using frameless stereotaxy was 0.9 ± 1.6 mm. In the study, 65% of lasers were exactly on the planned trajectory. Of the 30 that were not, the radial error = 2.6 ± 1.9 mm. Radial error of subtotal laser ablations was 0.5 ± 0.9 (range, 0-2.8 mm) and was not significantly different from 0.8 ± 1.7 (range, 0-7.1 mm) radial error of lasers with total ablations (P = .52). Lasers with radial error >0 mm resulted in an incomplete ablation in 26.7% of cases. CONCLUSION Skull pin-based frameless stereotaxy for MRgLITT results in consistent accuracy, with the majority of cases resulting in complete ablations. A significant proportion of lasers with RE >0 mm still result in complete ablations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3