Correlation versus gradient type motion detectors: the pros and cons

Author:

Borst Alexander1

Affiliation:

1. Max-Planck-Institute for Neurobiology, Systems and Computational NeurobiologyAm Klopferspitz 18, 82152 Martinsried-Planegg, Germany

Abstract

Visual motion contains a wealth of information about self-motion as well as the three-dimensional structure of the environment. Therefore, it is of utmost importance for any organism with eyes. However, visual motion information is not explicitly represented at the photoreceptor level, but rather has to be computed by the nervous system from the changing retinal images as one of the first processing steps. Two prominent models have been proposed to account for this neural computation: the Reichardt detector and the gradient detector. While the Reichardt detector correlates the luminance levels derived from two adjacent image points, the gradient detector provides an estimate of the local retinal image velocity by dividing the spatial and the temporal luminance gradient. As a consequence of their different internal processing structure, both the models differ in a number of functional aspects such as their dependence on the spatial-pattern structure as well as their sensitivity to photon noise. These different properties lead to the proposal that an ideal motion detector should be of Reichardt type at low luminance levels, but of gradient type at high luminance levels. However, experiments on the fly visual systems provided unambiguous evidence in favour of the Reichardt detector under all luminance conditions. Does this mean that the fly nervous system uses suboptimal computations, or is there a functional aspect missing in the optimality criterion? In the following, I will argue in favour of the latter, showing that Reichardt detectors have an automatic gain control allowing them to dynamically adjust their input–output relationships to the statistical range of velocities presented, while gradient detectors do not have this property. As a consequence, Reichardt detectors, but not gradient detectors, always provide a maximum amount of information about stimulus velocity over a large range of velocities. This important property might explain why Reichardt type of computations have been demonstrated to underlie the extraction of motion information in the fly visual system under all luminance levels.

Publisher

The Royal Society

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3