Low Power Adiabetic Logic System for Biomedical Applications

Author:

Mailsamy M.1,Rukkumani V.2,Srinivasan K.2

Affiliation:

1. Department of Electronics and Communication, CMS College of Engineering and Technology, Coimbatore 641032, India

2. Department of Electronics and Instrumentation Engineering, Sri Ramakrishna Engineering College, Coimbatore 641022, India

Abstract

There have been significant advances in sensors and device structures in the medical industry, particularly in implanted medical devices. Increasingly complex electronic circuitry may now be implanted in the human body thanks to compact, high-energy batteries and hermetic packaging. These gadgets must adhere to strict power consumption guidelines due to the battery recharging schedule. Designing energy-efficient circuits and systems becomes increasingly important as a result of this fact. Adiabatic circuits provide a hopeful alternative for traditional circuitry in case of low energy design. Because of power-clock phases synchronization complexity, designing and functionally verifying presenting 4-phase adiabatic circuitry takes longer. Accordingly, multiple clock generators are used typically and can reveal enhanced consumption of energy in the network of clock distribution. Furthermore, they are not suitable for designing in high-speed because of their clock skew management and high complexity issues. In this paper, TMEL (True multi-phase energy recovering logic), the first energyrecovering/adiabatic logic family is presented for biomedical applications, which functions using the scheme multiple-phase sinusoidal clocking. Moreover, a system of SCAL, a source-coupled variation with TMEL having enhanced energy efficiency and supply voltage scalability, is introduced. A novel true multi-phase Approach and Source-coupled adiabatic logic for energy effective communication system is proposed. The adiabatic logic is employed for both write and read side operation. The CMOS inverter is integrated with TMEL cascades, which in turn reduces leakage loss. In SCAL, the optimal performance at any operating circumstance is attained byan adjustable current source in each gate. SCAL, and TMEL, are capable of outperforming existing adiabatic logic families concerning operating speed and energy efficiency. The performance analysis was carried and simulated through 45 nm CMOS inverter in terms of leakage power, delay, and power consumption. In particular, for the clock rates that range from 10 MHz to 200 MHz, the proposed SCAL was more energy-efficient and less dissipative on comparing their pipelined or purely combinational CMOS counterparts. In biomedical equipment, the system may be included into the low-power design since it is energy efficient and very robust. Improvements in VLSI technology, such as increased dynamic range, low-voltage EEPROMs (electrically eraseable programmable ROMs), and specific sensor techniques, are also expected to contribute to advancements in implanted medical devices in the near future.

Publisher

American Scientific Publishers

Subject

Health Informatics,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3