COMPARATIVE EVALUATION OF THE 4TH GENERATION ELISA/CLIA ASSAYS USED FOR THE DIAGNOSIS OF HIV INFECTION IN THE RUSSIAN FEDERATION

Author:

Kireev D. E.1,Shipulin G. A.2,Semenov A. V.3,Tivanova E. V.1,Chulanov V. P.1,Kolyasnikova N. M.1,Zueva E. B.4,Galli C.5,Pokrovsky V. V.6

Affiliation:

1. Central Research Institute of Epidemiology of Rospotrebnadzor

2. Center of Strategical Planning and Biomedical Health Risks Management

3. Saint-Petersburg Pasteur Institute; North-Western State Medical University named after I.I.Mechnikov

4. Saint-Petersburg Pasteur Institute

5. Abbott Diagnostics.

6. Central Research Institute of Epidemiology of Rospotrebnadzor; Peoples’ Friendship University of Russia

Abstract

The aim of the work was to compare the five most widely used ELISA diagnostic kits on the territory of the Russian Federation, which are used for screening for HIV infection.Materials and methods. 5442 samples from visitors of diagnostic centers who came for blood donation for non-infectious analyses, cohorts with a high risk of HIV infection, as well as patients with potentially interfering conditions were used as a material for the study. Additionally, seroconversion panels and a panel of viral diversity were used to evaluate the analytical characteristics. The following test systems were compared: Architect HIV Ag/Ab Combo (Abbott), Genscreen Ultra HIV Ag-Ab (Bio-Rad), CombiBest HIV-1,2 AG/AT (Vector-Best), DS-ELISA-HIVAGAT-SCREEN (Diagnostic Systems), HIV-1,2-AG/AT (Medical-Biological Union).Conclusion. The diagnostic sensitivity of all tests was 100% with the exception of one (Medical-Biological Union), in which it turned out to be 99,54%. Diagnostic specificity ranged from 99,58% to 99,89%, but unexpectedly strongly depended on the test population, decreasing on a group with a high risk of HIV infection to 93,26% (Vector-Best). The convergence between initial and repeat reactive samples ranged from 100% (Abbott) to 89,51% (Vector-Best). The results of the analysis of seroconversion panels showed that the tests differed slightly from each other, receiving positive results from 22,12% (Diagnostic Systems) to 27,88% (Abbott) samples. When testing the panel of viral diversity, diagnostic tests from foreign manufacturers showed better results, revealing 100% (Abbott) and 85,9% (Bio-Rad). The smallest number of panel samples was detected by the kit of the Medical-Biological Union (52,1%). This work is the only study where the 4th generation ELISA kits, widely used in the Russian Federation for screening for HIV infection, were compared in an extensive sampling. The results obtained make it possible to evaluate the effectiveness of the use of the listed kits in routine diagnostic practice.

Publisher

Baltic Medical Education Center

Subject

Infectious Diseases,Public Health, Environmental and Occupational Health,Immunology

Reference17 articles.

1. UNAIDS data 2018. URL: http://www.unaids.org/sites/default/files/media_asset/unaids-data-2018_en.pdf.

2. Санитарно-эпидемиологические правила СП 3.1.5.2826–10 «Профилактика ВИЧ-инфекции» (ред. от 21.07.2016) / Постановление Главного государственного санитарного врача РФ от 21.07.2016 № 95. М., 2016. [Sanitary and epidemiological rules SP 3.1.5.2826–10 «Prevention of HIV infection» (ed. from 21.07.2016). Resolution of the Chief state sanitary doctor of the Russian Federation from 21.07.2016 № 95. Moscow, 2016 (In Russ.)].

3. ВИЧ-инфекция: Информационный бюллетень № 43. М.: ФНМЦ по профилактике и борьбе со СПИДом ФБУН «Центральный НИИ эпидемиологии» Роспотребнадзора, 2018. [HIV infection: Information Bulletin № 43. Moscow: Federal scientific and methodological center for AIDS prevention and control Central research Institute «Central research Institute of epidemiology» of Rospotrebnadzor, 2018 (In Russ)].

4. Hemelaar J. Implications of HIV diversity for the HIV-1 pandemic. J. Infect., 2013 May, Vol. 66, No. 5, pp. 391–400. URL: DOI: 10.1016/j.jinf.2012.10.026.

5. Gaudy C., Moreau A., Brunet S., Descamps J.M., Deleplanque P., Brand D., Barin F. Subtype B human immunodeficiency virus (HIV) type 1 mutant that escapes detection in a fourth generation immunoassay for HIV infection. J. Clin. Microbiol., 2004, Vol. 42, pp. 2847–2849. 6. Ly T.D., Plantier J.C., Leballais L., Gonzalo S., Lemée V., Laperche S. The variable sensitivity of HIV Ag/Ab combination assays in the detection of p24 Ag according to genotype could compromise the diagnosis of early HIV infection. J. Clin. Virol., 2012, Vol. 55, pp. 121–127. URL: DOI: 10.1016/j.jcv.2012.06.012.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3