ABSTRACT: Potatoes for industrial processing must have high dry matter, low sugar and free from damage or disease. The objective was to determine the ideal temperature and storage period of commercial cultivars for frying. Tubers of Asterix and Cronos cultivars were stored in a cold chamber (Gallant CMC4 Premium) inside plastic boxes at 6 and 8 °C with 85 to 95% humidity for 180 days. Accumulated mass loss (PMA), alcohol insoluble solids (SIA), total soluble sugars (AST), non-reducing sugars (ANR), reducing sugars (AR), polyphenoloxidase activity (PPO) and enzymatic and non-enzymatic browning were analyzed. The PMA of Asterix at 6 and 8 ºC and Cronos at 6 °C was higher. The SIA of both cultivars stored at 6 ºC were lower and AST, AR and ANR higher. Those parameters of Cronos and Asterix did not differ between temperature or storage period. The browning was greater in the fried sticks of Asterix and Cronos stored at 6 ºC (4 to 5) for 60 and 90 days and at 8 °C (2 to 3) for 180 days, respectively. The ideal temperature and storage period for Asterix and Cronos cultivars is 8 ºC for a maximum of 120 days due to non-enzymatic browning.