Author:
Uchic Michael D.,Dimiduk Dennis M.,Florando Jeffrey N.,Nix William D.
Abstract
ABSTRACTIn this paper we present a mechanical test methodology to explore specimen size effects in Ni3Al, where the overall test sample dimensions artificially limit the volume for substructure evolution and hence the availability of jogs/kinks along individual dislocation lines. The test methodology consists of using Focused Ion Beam milling to micromachine cylindrical compression samples that have diameters ranging from 5 to 20 microns into the surface of a bulk sample, which is followed by nanoindentation using a flat-ended tip to measure the mechanical properties of the microsamples in uniaxial compression. The initial test results show that there is a strong increase in the flow stress with decreasing sample size, although misfit between the flat indenter tip and the top surface of the compression samples complicates complete interpretation of the mechanical test results at this time.
Publisher
Springer Science and Business Media LLC
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献