Improving of Functioning Stability of Current Measuring Elements in Microprocessor Protections

Author:

Romaniuk F. A.1,Rumiantsev V. Yu.1,Rumiantsev Yu. V.1

Affiliation:

1. Belarusian National Technical University

Abstract

In the measuring elements of the current of microprocessor protection, the controlled values are usually the effective values of the fundamental harmonic of the currents. They are determined by the orthogonal components of the input signals, which are formed by digital Fourier filters. Due to the inertia of these filters, the time for obtaining reliable effective values is one or more periods of the input current, which mainly determines the speed of the measuring element. When the frequency of the input signal deviates from the nominal value, its effective values become oscillatory. As a result of this, unstable functioning of the specified organ may occur at current values that are close to the operation and return areas. To increase the speed of the measuring body, it is proposed to determine the effective value of the current by multiplying its value obtained using the orthogonal Fourier components by a correction factor. To ensure the stable functioning of the current organ, it is recommended to filter the effective current value using a digital moving average filter. Evaluation of the effectiveness of the proposed solutions has been carried out by the method of computational experiment using thedynamic simulation environment MATLAB-Simulink. The proposed solutions provide an increase in the speed of the current measuring organs and their stable operation when the frequency deviates from the nominal. As a result of the research, it has been found that the proposed digital current measuring organ in comparison with an organ based on the Fourier algorithm has a speed of 1.4-2 times greater. In addition, it functions stably both under the condition when the tripping current is less than the fault current, and in the case when the indicated currents are comparable when the frequency deviates from the nominal by ±2 Hz. The proposed digital measuring body can be used in many microprocessor-based current protection of electric installations.

Publisher

Belarusian National Technical University

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Fast-Response Method for Determining the Amplitude of a Signal in Microprocessor Automation and Control Systems with Frequency Fluctuations;ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations;2024-02-13

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3