Author:
Chen Shihao,Zhang Qiaoyue,Savini Giacomo,Zhang Shuangzhe,Huang Xiaomin,Yu Jinjin,Wang Yirang,Ning Rui,Huang Jinhai,Tu Ruixue
Abstract
PurposeTo evaluate measurement precision and to compare the Pentacam AXL (Oculus Optikgeräte, Wetzlar, German), a new optical biometer based on Scheimpflug imaging and partial coherence interferometry (PCI) with that of the OA-2000 biometer (Tomey, Nagoya, Japan), which combines swept-source optical coherence tomography (SS-OCT) and Placido-disk topography.MethodsAxial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km), astigmatism vectors J0, J45, and corneal diameter (CD) were measured in triplicate by two technical operators. Within-subject standard deviation (Sw), repeatability and reproducibility (2.77 Sw), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to assess the Pentacam AXL intra-observer repeatability and inter-observer reproducibility. Paired t-test and Bland-Altman plots were used to determine the agreement between the two biometers.ResultsThe new optical biometer had high intra-observer repeatability [all parameters evaluated had low CoV (<0.71%) and high ICC (>0.88)]. Inter-observer reproducibility was also excellent, with high ICC (>0.95) and low CoV (<0.52%). The 95% LoA between the new biometer and OA-2000 were insignificant for most of the parameters evaluated, especially for AL. However, the measurement agreement was moderate for CCT.ConclusionsIntra-observer repeatability and inter-observer reproducibility were excellent for all parameters evaluated using the new optical biometer based on Scheimpflug imaging and PCI. There was a high agreement between the two devices and hence could be clinically interchangeable for the measurement of most ocular parameters.
Reference40 articles.
1. Sources of error in intraocular lens power calculation;Norrby;J Cataract Refract Surg.,2008
2. Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: repeatability, reproducibility, and agreement;Wang;J Cataract Refract Surg.,2015
3. Comparison of a new Scheimpflug imaging combined with partial coherence interferometry biometer and a low-coherence reflectometry biometer;Ruizmesa;J Cataract Refract Surg.,2017
4. Overview of the repeatability, reproducibility, and agreement of the biometry values provided by various ophthalmic devices;Rozema;Am J Ophthalmol,2014
5. Comparison of axial length, corneal curvature, and anterior chamber depth measurements of 2 recently introduced devices to a known biometer;Shajari;Am J Ophthalmol,2017
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献