Technical Design Report for a Carbon-11 Treatment Facility

Author:

Penescu Liviu,Stora Thierry,Stegemann Simon,Pitters Johanna,Fiorina Elisa,Augusto Ricardo Dos Santos,Schmitzer Claus,Wenander Fredrik,Parodi Katia,Ferrari Alfredo,Cocolios Thomas E.

Abstract

Particle therapy relies on the advantageous dose deposition which permits to highly conform the dose to the target and better spare the surrounding healthy tissues and organs at risk with respect to conventional radiotherapy. In the case of treatments with heavier ions (like carbon ions already clinically used), another advantage is the enhanced radiobiological effectiveness due to high linear energy transfer radiation. These particle therapy advantages are unfortunately not thoroughly exploited due to particle range uncertainties. The possibility to monitor the compliance between the ongoing and prescribed dose distribution is a crucial step toward new optimizations in treatment planning and adaptive therapy. The Positron Emission Tomography (PET) is an established quantitative 3D imaging technique for particle treatment verification and, among the isotopes used for PET imaging, the 11C has gained more attention from the scientific and clinical communities for its application as new radioactive projectile for particle therapy. This is an interesting option clinically because of an enhanced imaging potential, without dosimetry drawbacks; technically, because the stable isotope 12C is successfully already in use in clinics. The MEDICIS-Promed network led an initiative to study the possible technical solutions for the implementation of 11C radioisotopes in an accelerator-based particle therapy center. We present here the result of this study, consisting in a Technical Design Report for a 11C Treatment Facility. The clinical usefulness is reviewed based on existing experimental data, complemented by Monte Carlo simulations using the FLUKA code. The technical analysis starts from reviewing the layout and results of the facilities which produced 11C beams in the past, for testing purposes. It then focuses on the elaboration of the feasible upgrades of an existing 12C particle therapy center, to accommodate the production of 11C beams for therapy. The analysis covers the options to produce the 11C atoms in sufficient amounts (as required for therapy), to ionize them as required by the existing accelerator layouts, to accelerate and transport them to the irradiation rooms. The results of the analysis and the identified challenges define the possible implementation scenario and timeline.

Publisher

Frontiers Media SA

Subject

General Medicine

Reference143 articles.

1. High purity radioactive beams at the Bevalac;Alonso;IEEE Trans Nucl Sci.,1979

2. BEARS: radioactive ion beams at Berkeley;Powell;Nucl Instrum Methods Phys Res A: Accel Spectrom Detect Assoc Equip.,2000

3. Progress of the Proton-Ion Medical Machine Study (PIMMS)

4. Post-accelerated beams at ISOLDE;Kadi;J Phys G: Nucl Part Phys.,2017

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Dose estimation using in-beam positron emission tomography: Demonstration for 11C and 15O ion beams;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-09

2. Quasi-real-time range monitoring by in-beam PET: a case for 15O;Scientific Reports;2023-11-01

3. A novel smart rad-hard fast detection system for Radioactive Ion Beam Tagging and Diagnostics;EPJ Web of Conferences;2023

4. Feasibility of triple gamma ray imaging of 10C for range verification in ion therapy;Physics in Medicine & Biology;2022-08-02