Feasibility of triple gamma ray imaging of 10C for range verification in ion therapy

Author:

Mohammadi AkramORCID,Tashima HideakiORCID,Takyu Sodai,Iwao Yuma,Akamatsu GoORCID,Kang Han GyuORCID,Obata Fujino,Nishikido Fumihiko,Parodi KatiaORCID,Yamaya Taiga

Abstract

Abstract Objective. In carbon ion therapy, the visualization of the range of incident particles in a patient body is important for treatment verification. In-beam positron emission tomography (PET) imaging is one of the methods to verify the treatment in ion therapy due to the high quality of PET images. We have shown the feasibility of in-beam PET imaging of radioactive 15O and 11C ion beams for range verification using our OpenPET system. Recently, we developed a whole gamma imager (WGI) that can simultaneously work as PET, single gamma ray and triple gamma ray imaging. The WGI has high potential to detect the location of 10C, which emits positrons with a simultaneous gamma ray of 718 keV, within the patient’s body during ion therapy. Approach. In this work, we focus on investigating the performance of WGI for 10C imaging and its feasibility for range verification in carbon ion therapy. First, the performance of the WGI was studied to image a 10C point source using the Geant4 toolkit. Then, the feasibility of WGI was investigated for an irradiated polymethyl methacrylate (PMMA) phantom with a 10C ion beam at the carbon therapy facility of the Heavy Ion Medical Accelerator in Chiba. Main results. The average spatial resolution and sensitivity for the simulated 10C point source at the centre of the field of view were 5.5 mm FWHM and 0.010%, respectively. The depth dose of the 10C ion beam was measured, and the triple gamma image of 10C nuclides for an irradiated PMMA phantom was obtained by applying a simple back projection to the detected triple gammas. Significance. The shift between Bragg peak position and position of the peak of the triple gamma image in an irradiated PMMA phantom was 2.8 ± 0.8 mm, which demonstrates the capability of triple gamma imaging using WGI for range verification of 10C ion beams.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference67 articles.

1. GEANT4—a simulation toolkit;Agostinelli;Nucl. Instrum. Methods Phys. Res. A,2003

2. Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors;Akamatsu;Phys. Med. Biol.,2019

3. Geant4 developments and applications;Allison;IEEE Trans. Nucl. Sci.,2006

4. Radiotherapy with beams of carbon ions;Amaldi;Rep. Prog. Phys.,2005

5. New developments of 11C post-accelerated beams for hadron therapy and imaging;Augusto;Nucl. Instrum. Methods Phys. Res. B,2016

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Investigation of intra-fractionated range guided adaptive proton therapy: I. On-line PET imaging and range measurement;Physics in Medicine & Biology;2024-07-17

2. Radiation shielding assessment for interventional radiology personnel: Geant4 dosimetry of lead-free compositions;Biomedical Physics & Engineering Express;2024-02-14

3. In-beam whole gamma imaging of a 10C ion beam: a phantom study;2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD);2023-11-04

4. The Correlation Between Scatter Detector Performance and Spatial Resolution in a Ring-Shaped Compton Imaging System;IEEE Transactions on Radiation and Plasma Medical Sciences;2023-07

5. Short-lived radioactive 8Li and 8He ions for hadrontherapy: a simulation study;Physics in Medicine & Biology;2023-02-23

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3