Pulmonary nitric oxide in astronauts before and during long-term spaceflight

Author:

Karlsson Lars L.,Gustafsson Lars E.,Linnarsson Dag

Abstract

Introduction: During exploratory space flights astronauts risk exposure to toxic planetary dust. Exhaled nitric oxide partial pressure (PENO) is a simple method to monitor lung health by detecting airway inflammation after dust inhalation. The turnover of NO in the lungs is dependent on several factors which will be altered during planetary exploration such as gravity (G) and gas density. To investigate the impacts of these factors on normal PENO, we took measurements before and during a stay at the International Space Station, at both normal and reduced atmospheric pressures. We expected stable PENO levels during the preflight and inflight periods, with lower values inflight. With reduced pressure we expected no net changes of PENO.Material and methods: Ten astronauts were studied during the pre-flight (1 G) and inflight (µG) periods at normal pressure [1.0 ata (atmospheres absolute)], with six of them also monitored at reduced (0.7 ata) pressure and gas density. The average observation period was from 191 days before launch until 105 days after launch. PENO was measured together with estimates of alveolar NO and the airway contribution to the exhaled NO flux.Results: The levels of PENO at 50 mL/s (PENO50) were not stable during the preflight and inflight periods respectively but decreased with time (p = 0.0284) at a rate of 0.55 (0.24) [mean (SD)] mPa per 180 days throughout the observation period, so that there was a significant difference (p < 0.01, N = 10) between gravity conditions. Thus, PENO50 averaged 2.28 (0.70) mPa at 1 G and 1.65 (0.51) mPa during µG (−27%). Reduced atmospheric pressure had no net impact on PENO50 but increased the airway contribution to exhaled NO.Discussion: The time courses of PENO50 suggest an initial airway inflammation, which gradually subsided. Our previous hypothesis of an increased uptake of NO to the blood by means of an expanded gas-blood interface in µG leading to decreased PENO50 is neither supported nor contradicted by the present findings. Baseline PENO50 values for lung health monitoring in astronauts should be obtained not only on ground but also during the relevant gravity conditions and before the possibility of inhaling toxic planetary dust.

Funder

Swedish National Space Agency

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3