Defects and Safety of NiTi Root Canal Instruments: A Systematic Review and Meta-Analysis

Author:

Yon Madeline Jun-yu,Tang Mark Ho-yeung,Cheung Gary Shun-pan

Abstract

Aim: To review the reported defect and fracture rates of various NiTi instrumentation systems and identify factors that may influence the chance of NiTi file separation clinically.Data Sources: PubMed, EMBASE, and SCOPUS with controlled vocabulary and keywords in various combinations to identify articles that reported on the defects and/or fracture of NiTi instrument used clinically (Jan 1980 till Aug 2021), with additional search manually by going through the list of references of the initially screened articles. Those satisfying the inclusion and exclusion criteria were entered into the analysis.Study Eligibility Criteria, Participants, and Interventions: All studies from the said databases reporting on NiTi root canal instruments that were deformed or separated during normal clinical use.Study Appraisal and Synthesis Methods: Studies with data available and suitable for meta-analysis were grouped according to the general design of the NiTi instruments for comparison. Safety quotient value was calculated based on the rate of instrument distortion and fracture.Results: Various instrument designs exhibited different incidences of distortion and fracture, hence a different “safety quotient” (ratio of the amount of deformed instruments to that of fractures in use). Heat-treated files showed the highest safety quotient value. All brands of NiTi file demonstrated a statistically significantly lower incidence of fracture, if treated as disposable instruments after clinical use in a patient.Limitations: Inclusion of articles written in English only, and grouping of file systems into general design types in the analysis.Conclusions and Implications of Key Findings: NiTi endodontic files should be scrutinized for defects before being used in the root canal. Disposing the NiTi instruments after clinical use in a patient (so-called “single use”) is recommended for minimizing fracture clinically. Certain instrument designs tend to show discernible deformation before they should fracture in the next use.

Publisher

Frontiers Media SA

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3