Introduction/Objective. of this study is to use scanning electron microscopy (SEM) analysis to examine surfaces of new and same sets of Ni-Ti instruments after canal preparations, to check their suspectability to corrosion. Methods. In this study, we used five different endodontic Ni-Ti instruments: K3, Mtwo, ProTaper Universal, HyFlex and BioRaCe. Instruments were analyzed before and after preparation of canals of different curvature, using SEM (150?2000 ?). Results. Corrosion of the working part was observed in 5.5% of new Ni-Ti instruments of the K3 system (apical and middle segment), in 5.5% of Mtwo instruments (apical third), and in 11.1% of ProTaper Universal systems (apical and middle third). Corrosion was not observed on the new instruments of the HyFlex and BioRaCe kits. After instrumentation, disinfection, and sterilization, corrosion was observed in all sets of K3 and ProTaper Universal systems and in all HyFlex instruments of the first group. Corrosion was observed in the HyFlex system in the second group in 16.7% of instruments (apical and middle third) and in the third 83.3% in the apical and 66.7% in the middle segment. In the Mtwo set, corrosion was observed in 16.7% of instruments in the first (apical and middle third), in the second group in 33.3% of instruments in the apical part and 50% in the middle third, while in the third group, corrosion was observed in 16.7% of instruments in the middle third of instruments. Conclusion. Rotary Ni-Ti instruments K3 and ProTaper Universal are susceptible to corrosion in a very high percentage. Ni-Ti systems with post-heat treatment of the working part (HyFlex) are somewhat more resistant to corrosion, while in Ni-Ti systems with electropolished surface (BioRaCe), corrosion is not observed.
Publisher
National Library of Serbia
Reference30 articles.
1. Živković S, Nešković J, Popović-Bajić M, Medojević-Jovanović M. The efficiency of canal cleaning with reciprocating movements instruments-SEM study. Srp Arh Celok Lek. 2020;148(3-4):148-52.
2. Han-Hsing Lin J, Karabucak B, Lee SM. Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments. An in vitro study. J Dent Sci. 2021;16(2):738-43.
3. de Carvalho KKT, Petean IBF, Silva-Sousa AC, de Camargo RV, Mazzi-Chaves JF, Silva-Sousa YTC, et al. Impact of several NiTithermally treated instrumentation systems on biomechanical preparation of curved root canals in extracted mandibular molars. Int Endod J. 2022;55(1):124-36.
4. Koch G, Varney J, Thompson N, Moghissi O, Gould M, Payer J. International measures of prevention, application, and economics of corrosion technologies study: Technical report. Houston, TX: NACE International. 2016. Available from: http://impact.nace.org/ documents/Nace-International-Report.pdf
5. Eggert C, Peters O, Barbakow F. Wear of Nickel-Titanium Lightspeed Instruments Evaluated by Scanning Electron Microscopy. J Endod. 1999;25(7):494-7.