Body mass index, basal insulin and glycemic control in children with type 1 diabetes treated with the advanced hybrid closed loop system remain stable - 1-year prospective, observational, two-center study

Author:

Seget Sebastian,Jarosz-Chobot Przemysława,Ochab Agnieszka,Polanska Joanna,Rusak Ewa,Witoszek Paulina,Chobot Agata

Abstract

BackgroundInformation on the influence of insulin treatment using advanced hybrid closed loop systems (AHCL) on body weight of young patients with type 1 diabetes (T1D) is scarce. The aim of this study was to observe whether there were any changes in body mass index (BMI) of children and adolescents with T1D treated using the Medtronic Minimed 780G AHCL after 1 year of follow up and to analyze potential associations between these changes and the insulin doses.Materials and methodsFor 50 children and adolescents (age 5.4-16.8 years, 24 (48%) boys, T1D for 3.9 ± 2.56 years) using an AHCL system anthropometric and AHCL data were collected prospectively. BMI Z-scores and two-week AHCL records obtained after AHCL enrollment were compared with data after 6 months and also 1 year after starting AHCL.ResultsThe BMI Z-score of the patients at 1 year follow-up did not change from time of AHCL initiation (0.51 ± 2.79 vs 0.57 ± 2.85, p>0.05). There was a slight increase in total daily insulin per kg of body weight (0.67 ± 0.21 U/kg vs 0.80 ± 0.21 U/kg, p <0.001), but the percent of basal insulin was unchanged (34.88 ± 6.91% vs 35.08 ± 6.30%, p>0.05). We observed also no change (AHCL start vs after 1 year) in glycemic control parameters: average sensor glucose (131.36± 11.04 mg/dL vs 132.45 ± 13.42 mg/dL, p>0.05), coefficient of variation (34.99± 5.17% vs 34.06 ± 5.38%, p>0.05), glucose management indicator (6.45 ± 0.26% vs 6.48 ± 0.32%, p>0.05), and time spent in the range of 70–180 mg/dL (79.28 ± 8.12% vs 80.40 ± 8.25%, p>0.05).ConclusionDuring the 1 year of follow-up the BMI of children and adolescents with T1D treated with an AHCL system remained stable. Although there was a slight increase in the total daily insulin dose, the percent of basal insulin was unchanged. The patients maintained recommended glycemic control.

Funder

Silesian University of Technology

Publisher

Frontiers Media SA

Subject

Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3