A 3-Year Single Center Experience With Left Atrial Pressure Remote Monitoring: The Long and Winding Road

Author:

Restivo Attilio,D'Amario Domenico,Paglianiti Donato Antonio,Laborante Renzo,Princi Giuseppe,Cappannoli Luigi,Iaconelli Antonio,Galli Mattia,Aspromonte Nadia,Locorotondo Gabriella,Burzotta Francesco,Trani Carlo,Crea Filippo

Abstract

BackgroundDespite continuous advancement in the field, heart failure (HF) remains the leading cause of hospitalization among the elderly and the overall first cause of hospital readmission in developed countries. Implantable hemodynamic monitoring is being tested to anticipate the clinical exacerbation onset, potentially preventing an emergent acute decompensation. To date, only pulmonary artery pressure (PAP) sensor received the approval to be implanted in symptomatic heart failure patients with reduced ejection fraction. However, PAP's indirect estimation of left ventricular filling pressure can be inaccurate in some contexts.MethodsThe VECTOR-HF study (NCT03775161) is examining the safety, usability and performance of the V-LAP system, a latest-generation device capable of continuously monitoring left atrial pressure (LAP). In our center, five advanced HF patients have been enrolled. After confirmation of the transmitted data reliability, LAP trends and waveforms have guided therapy optimization. The aim of this work is to share clinical insights from our center preliminary experience with V-LAP application.ResultsOver a median follow-up time of 18 months, LAP–based therapy optimization managed to reduce intracardiac pressure over time and no hospital readmission occurred. This result was paralleled by an improvement in both functional capacity (6MWT distance 352.5 ± 86.2 meters at baseline to 441.2 ± 125.2 meters at last follow-up) and quality of life indicators (KCCQ overall score 63.82 ± 16.36 vs. 81.92 ± 9.63; clinical score 68.47 ± 19.48 vs. 83.70 ± 15.58).ConclusionPreliminary evidence from V-LAP application at our institution support a promising efficacy. However, further study is needed to confirm the technical reliability of the device and to exploit the clinical benefit of left-sided hemodynamic remote monitoring.

Funder

Università Cattolica del Sacro Cuore

Publisher

Frontiers Media SA

Subject

Cardiology and Cardiovascular Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3