Investigation on Residual Mechanical Properties of Galvanized Iron Cold-Formed Steel Sections Exposed to Elevated Temperatures

Author:

Sabu Sam VarunORCID,N AnandORCID,K Marak Garry WegaraORCID,Lyngdoh Garry Robson,Alengaram Johnson,Diana Andrushia

Abstract

Cold-formed steel (CFS) sections are used to construct medium and low-rise structures designed to carry small-scale loads. CFS sections are manufactured without the application of heat. Therefore, it is crucial to comprehend the properties of CFS sections which are exposed to fire or elevated temperatures. To simulate the real- time fire exposure, an ISO Standard fire curve was used to heat the CFS sections. The objective of the study is to assess the residual mechanical strength of exposed sections after the elevated temperature test. The study aims to compile data for forecasting the degeneration of elements and to ascertain whether the structural components can be reused or replaced. The CFS sections were subjected to different temperatures, and after heating, two cooling methods were used to bring down to room temperature. The characteristics of the retrieved specimens, taken from exposed CFS sections were assessed using a tensile coupon test. The residual properties such as ultimate strength, yield strength, and elastic modulus were examined and reported. The influence of heating and cooling is more pronounced from the test results. A reduction in the yield and ultimate strength was noticed, and it was found to decrease as the heating intensity increases for air and water cooling respectively. In the case of yield and ultimate strength, the strength reduction is critical beyond 60 minutes. The elastic modulus was also found to be reducing with a similar trend. Based on the test results, reduction factors are proposed for ultimate strength, yield strength and elastic modulus. Reduction factors obtained for yield strength under 60 minutes of heating for air and water cooling is 0.575 and 0.557 respectively. In 120 minutes, the values are 0.400 and 0.329. Reduction factors obtained for ultimate strength under 60 minutes of heating for air and water cooling is 0.586 and 0.566 respectively. For 120 minutes, the values are 0.331 and 0.313.

Publisher

EJSE International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3