Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures

Author:

Sam Varun Sabu1,Nammalvar Anand1,Andrushia Diana2,Gurupatham Beulah Gnana Ananthi3ORCID,Roy Krishanu4ORCID

Affiliation:

1. Department of Civil Engineering, Karunya Institute of Technology and Sciences, Coimbatore 641114, India

2. Department of Electronics and communications Engineering Karunya, Institute of Technology and Sciences, Coimbatore 641114, India

3. Division of Structural Engineering, College of Engineering, Guindy Campus, Anna University, Chennai 600025, India

4. School of Engineering, The University of Waikato, Hamilton 3216, New Zealand

Abstract

Cold-formed steel (CFS) sections have become popular in construction due to several advantages over structural steel. However, research on the performance of galvanized iron (GI)-based CFS under high temperatures, especially regarding its flexural behavior, has been limited. This study extensively investigates how GI-based CFS beams with varying spans behave under elevated temperatures and subsequent cooling using air and water. This study examines the impact of temperature loading and compares the effectiveness of air- and water-cooling methods. Experimental results are validated and analyzed alongside findings from finite element modeling (FEM) using ABAQUS (2019_09_13-23.19.31) and the Direct Strength Method (DSM). Additionally, this study conducts a parametric investigation to assess how beam span influences flexural capacity. Among beams heated to the same temperature, those cooled with water show slightly lower load capacities compared to those cooled with air. The highest load capacity observed is 64.3 kN for the reference specimen, while the lowest is 26.2 kN for the specimen heated for 90 min and cooled with water, a 59.27% difference between them. Stiffness decreases as heating duration increases, with the reference section exhibiting significantly higher stiffness compared to the section heated for 90 min and cooled with water, with a 92.76% difference in stiffness. As heating duration increases, ductility also increases. Various failure modes are observed based on different heating and cooling conditions across different beam spans. This study provides insights into how GI-based CFS beams perform under temperature stress and different cooling scenarios, contributing valuable data for structural design and safety considerations in construction.

Publisher

MDPI AG

Reference23 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3