In vitro comparison of two types of digital X-ray sensors for proximal caries detection validated by micro-computed tomography

Author:

Heck Katrin1ORCID,Litzenburger Friederike1,Ullmann Verena1,Hoffmann Lea1,Kunzelmann Karl-Heinz1

Affiliation:

1. Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University Munich, Goethestr. 70, 80336, Munich, Germany

Abstract

Objectives: We aimed to compare the diagnostic accuracy of two intraoral digital X-ray sensors—the charged-coupled device (CCD) and complementary metal-oxide-semiconductor (CMOS)—for proximal caries detection in permanent molar and premolar teeth. Micro-CT served as the reference standard. Methods: 250 samples were mounted in three-dimensional (3D)-printed phantoms, and their proximal surfaces were evaluated by ICDAS criteria directly to create a balanced sample. Bitewing radiography was conducted using 3D-constructed X-ray phantoms with a CCD sensor at a 0.08 s and a CMOS sensor at 0.12 and 0.16 s exposure time. Two examiners determined the diagnostic decisions twice at appropriate intervals. Three diagnostic thresholds for sound surfaces and enamel and dentin caries were defined and presented in a cross-table. Sensitivity and specificity values and overall accuracy were calculated, and receiver operating curves were generated and compared. Reliability assessment was performed using linear weighted κ statistics. Results: The overall accuracies between the reference standard and different sensors and exposure times were 63.1% (CCD), 67.1% (CMOS sensor at 0.12 s) and 70.7% (CMOS sensor at 0.08 s). High specificity but low sensitivity values were found for all examination conditions at all thresholds. The area under the curve comparison values revealed no significant difference between sensor types and exposure times. Linear-weighted κ analysis revealed almost perfect agreement for all assessments. Conclusion: No significant difference was found for diagnostic performance of proximal caries detection between the different sensors and exposure times. The increased exposure time did not lead to a significant diagnostic benefit.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3