Near-infrared reflection at 780 nm for detection of early proximal caries in posterior permanent teeth in vitro

Author:

Heck Katrin1ORCID,Litzenburger Friederike1,Geitl Thomas1,Kunzelmann Karl-Heinz1

Affiliation:

1. Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany

Abstract

Objectives: The aim of this in vitro study was to evaluate the diagnostic potential of near-infrared reflection at 780 nm (NIRR780nm) for early proximal caries detection on the occlusal, buccal and oral surfaces of molars and premolars under simulated, clinically relevant conditions. The findings were validated by micro-computed tomography (µCT). Methods: Bitewing radiography (BWR) was used as a comparative diagnostic method. 250 sound or decayed permanent teeth were examined using NIRR780nm and BWR. The NIRR780nm findings were evaluated using yes/no decisions depending on the presence of caries lesions, as the enamel-dentin junction was not detectable in the majority of samples. All NIRR780nm, BWR and µCT findings were obtained twice by two trained examiners. NIRR780nm images were evaluated both occlusally alone and combined occlusally, lingually and buccally. All findings were presented in a cross-table. Sensitivity, specificity and area under the curve (AUC) values were calculated. Reliability assessment was performed using κ statistics. Results: Underestimation of caries was observed for NIRR780nm in 26.0% of all surfaces and for BWR in 32.8% of all surfaces. Overestimation was 10.0% for NIRR780nm and 0.4% for BWR. Trilateral NIRR780nm assessment exhibited an overall accuracy of 67.2 %, an underestimation of 13.6% and an overestimation of 19.2%. Trilateral NIRR780nm exhibited 63.0% sensitivity and 69.6% specificity, while BWR exhibited 26.7% sensitivity but 100% specificity for proximal caries detection. Conclusion: NIRR780nm is not suitable for reliable detection of early proximal caries, even with the application of an ideal setup and optimized in vitro conditions.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3