Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts

Author:

Garcia Annelisa Moura1,Assunção-Jr Antonildes N.1,Dantas-Jr Roberto Nery1,Parga Jose Rodrigues1,Ganem Fernando1

Affiliation:

1. Sirio-Libanes Hospital, Sao Paulo, SP, Brazil

Abstract

Objective: Qualitative and quantitative image analysis between Iopamidol-370 and Ioversol-320 in stents´ evaluation by coronary computed tomography angiography (CTA). Methods: Sixty-five patients with low-risk stable angina undergoing stent follow-up with coronary CTA were assigned to Iopamidol I-370 (n = 33) or Ioversol I-320 (n = 32) in this prospective, double-blind, non-inferiority, randomized trial. Stent lumen image quality was graded by 5-point Likert Scale. Lumen mean attenuation was measured at native coronary segments: pre-stent, post-stent, distal segments and at coronary plaques. Lumen attenuation increase (LAI) ratio was calculated for all stents. Heart rate (HR) variation, premature heart beats (PHB), heat sensation (HS), blooming and beam hardening were also assessed. Results: Image quality was similar between groups, with no significant difference (Likert score 4.48 ± 0.75 vs 4.54 ± 0.65, p = 0.5). There were similarities in LAI ratio between I-370 and I-320 (0.39 ± 0.42 vs 0.48 ± 0.44 HU, p = 0.08). Regarding lumen mean attenuation at native coronary segments, a significant difference was observed, with I-320 presenting lower values, including contrast mean attenuation in distal segments. After statistical multivariate analysis, three variables correlated with stent image quality: 1) stent diameter, 2) HR variation and 3) stent lumen LAI ratio. Conclusions: There was no significant difference between Iopamidol-370 mgI ml−1 and Ioversol-320 mgI ml−1 contrasts regarding overall stent lumen image quality, which was mainly influenced by stent diameter, HR and LAI ratio. Advances in knowledge: Coronary CTA allows adequate stents' visualization and image quality is influenced by stent diameter, HR variation and LAI ratio. Stents' image quality showed no difference between different concentration contrasts (I-370 vs. I-320); however, higher concentration contrasts may provide an improved overall visualization, especially regarding coronary distal segments.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3