Measurability and reliability of assessments of root length and marginal bone level in cone beam CT and intraoral radiography: a study of adolescents

Author:

Al-Okshi Ayman12,Paulsson Liselotte1,Rohlin Madeleine1,Ebrahim Eman13,Lindh Christina1

Affiliation:

1. Faculty of Odontology, Malmö University, Malmö, Sweden

2. Department of Oral Medicine and Radiology, Faculty of Dentistry, Sebha University, Sebha, Libya

3. Department of Orthodontics, Faculty of Dentistry, Sebha University, Sebha, Libya

Abstract

Objectives: To evaluate measurability and reliability of measurements of root length and marginal bone level in CBCT, periapical (PA) and bitewing (BW) radiographs. Methods: CBCT of both jaws, PA of maxillary incisors and posterior BW radiographs of 10 adolescents (mean age 13.4) were selected. The radiographs comprised part of the baseline examinations of a trial of orthodontic treatment. Six raters assessed measurability and measured root length and marginal bone level. Three raters repeated their assessments. Measurability was expressed as frequency of interpretable sites and reliability as intraclass correlation coefficient (ICC). Results: Measurability was 100 % in CBCT and 95 % in PA of maxillary incisors for root length measurements. For marginal bone level, measurability was 100 % in CBCT, 76 % in PA and 86 % in posterior BW. Mean ICC for interrater reliability for root length measurements in CBCT was 0.88 (range 0.27–0.96 among different teeth) and 0.69 in PA of maxillary incisors. For marginal bone level measurements, mean ICC was 0.4 in CBCT, 0.38 in PA of maxillary incisors and 0.4 in posterior BW. Intrarater reliability varied among methods, root length or marginal bone level and among raters, except for root length measurements in CBCT, which presented high reliability (above 0.8) for all raters. Conclusions: As measurability and reliability were high for root length measurements in CBCT, this may be the method of choice for scientific analyses in orthodontics. For clinical praxis, we recommend PA following the “as low as diagnostically acceptable” principle, as clinical decisions seem to be influenced only when severe root resorption occurs.

Publisher

British Institute of Radiology

Subject

General Dentistry,Radiology Nuclear Medicine and imaging,General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3